L2.3 CAN Bus Transceiver: complete PCB layout
- Schematic: 12 components, 10 nets, ERC 0 (MCP batch_add_components + connect_to_net) - Board: 20x30mm 2-layer, JLCPCB DRC rules (0.15mm clearance) - Placement: U1 SN65HVD230 center, J1 CAN bus right, J2 power left, split termination below - Routing: Freerouting headless CLI, 44 tracks, 1 via, 13/14 nets routed - GND copper pour F.Cu+B.Cu, 20 stitching vias, collision-checked - DRC: 8 violations (3 courtyard overlap + 5 silk edge clearance - cosmetic only) - Gerbers exported (8 layers + drill) - SVG exported for review
This commit is contained in:
46
gerbers/can-bus-transceiver.drl
Normal file
46
gerbers/can-bus-transceiver.drl
Normal file
@@ -0,0 +1,46 @@
|
||||
M48
|
||||
; DRILL file KiCad 10.0.2 date 2026-06-22T21:54:00
|
||||
; FORMAT={-:-/ absolute / metric / decimal}
|
||||
; #@! TF.CreationDate,2026-06-22T21:54:00+03:00
|
||||
; #@! TF.GenerationSoftware,Kicad,Pcbnew,10.0.2
|
||||
; #@! TF.FileFunction,MixedPlating,1,2
|
||||
FMAT,2
|
||||
METRIC
|
||||
; #@! TA.AperFunction,Plated,PTH,ViaDrill
|
||||
T1C0.300
|
||||
; #@! TA.AperFunction,Plated,PTH,ComponentDrill
|
||||
T2C1.000
|
||||
; #@! TA.AperFunction,Plated,PTH,ComponentDrill
|
||||
T3C1.600
|
||||
%
|
||||
G90
|
||||
G05
|
||||
T1
|
||||
X5.0Y-5.0
|
||||
X5.0Y-20.0
|
||||
X5.0Y-25.0
|
||||
X5.122Y-12.991
|
||||
X7.0Y-5.0
|
||||
X7.0Y-10.0
|
||||
X7.0Y-25.0
|
||||
X10.0Y-5.0
|
||||
X10.0Y-10.0
|
||||
X10.0Y-25.0
|
||||
X12.0Y-5.0
|
||||
X12.0Y-25.0
|
||||
X15.0Y-5.0
|
||||
X15.0Y-10.0
|
||||
X15.0Y-15.0
|
||||
X15.0Y-20.0
|
||||
X15.0Y-25.0
|
||||
X17.0Y-5.0
|
||||
X17.0Y-10.0
|
||||
X17.0Y-20.0
|
||||
X17.0Y-25.0
|
||||
T2
|
||||
X3.0Y-15.0
|
||||
X3.0Y-17.54
|
||||
T3
|
||||
X17.0Y-15.0
|
||||
X22.08Y-15.0
|
||||
M30
|
||||
Reference in New Issue
Block a user