4.3 KiB

Network Variables (NVL) for Node-RED

This folder describes the network variable setup used for CODESYS ↔ Node-RED communication. The PLC sends light/boiler status to Node-RED and receives commands from Node-RED over UDP.

Overview

Direction CODESYS name Node-RED role Content
PLC → Node-RED NVL_Out (Sender) Receive UDP Light states + boiler status
Node-RED → PLC NVL_In (Receiver) Send UDP Light commands + boiler commands
  • Protocol: UDP
  • Typical interval: 50 ms cyclic (configurable in CODESYS)
  • Payload: Binary (struct layout) or see Payload layout for Node-RED for parsing.

1. NVL_Out (PLC → Node-RED)

Purpose: PLC sends current light outputs and boiler status so Node-RED can forward them to Home Assistant / MQTT.

Variables sent (in order):

Variable Type Description
l_masterBedroom struct_room_outs 12 BOOLs (l_1..l_6, l_1_status..l_6_status)
l_masterBathroom struct_room_outs same
l_bedroom_1 .. l_bedroom_2 struct_room_outs same
l_bathroom, l_guestWc, l_kitchen, l_pantry struct_room_outs same
l_livingRoom, l_dinningRoom, l_entrance, l_hallway struct_room_outs same
l_outVeranda, l_outFront, l_outBack, l_outSide struct_room_outs same
boiler_status struct_boiler_status state, relay_output, on_time_minutes, remaining_minutes, emergency_active, time_limit_reached, error_state, error_code

In CODESYS: Create an NVL Sender (Network Variable List), bind it to the NVL_Out structure (the same struct as in GVL_NVL_placeholders.gvlNVL_Out). Set protocol to UDP, destination IP/port to your Node-RED host, task and interval (e.g. EtherCAT_Task, 50 ms).


2. NVL_In (Node-RED → PLC)

Purpose: Node-RED sends commands (HA ON/OFF, Zigbee toggle edges, boiler on/off, etc.) so the PLC can drive lights and the boiler.

Variables received (in order):

Variable Type Description
masterBedroom .. side (15 rooms) struct_room_cmds ha_l1_on, ha_l1_off, ... ha_l6_on, ha_l6_off, zigbee_sw1..6, ha_all_on, ha_all_off
boiler struct_boiler_cmd ha_on, ha_off, schedule_on, schedule_off, emergency_stop, max_on_time_minutes

In CODESYS: Create an NVL Receiver, bind it to the NVL_In structure. Set protocol to UDP, listen port, task and interval. The PLC will overwrite NVL_In with received data each cycle.

In Node-RED: Use a UDP out node to the PLC IP and NVL Receiver port. Send one UDP packet per update with the same binary layout as NVL_In; see nodered-payload.md for building the buffer.


3. CODESYS configuration steps

  1. Add NVL Sender

    • Device tree → Add Object → Network Variable List (Sender).
    • Set protocol to UDP, destination IP = Node-RED host, port = e.g. 5555 (receive port on Node-RED).
    • Add variables: add the entire NVL_Out struct (or add each member; see CODESYS help).
    • Set task (e.g. EtherCAT_Task) and interval (e.g. T#50ms).
  2. Add NVL Receiver

    • Add Object → Network Variable List (Receiver).
    • Set protocol to UDP, listen port = e.g. 5556.
    • Add variables: add the entire NVL_In struct.
    • Set task and interval.
  3. Bind to GVL

    • Either the NVL Sender/Receiver are the GVL variables (you map the NVL to the symbols NVL_Out and NVL_In), or you copy NVL → GVL in the program. Typically you bind the NVL list to a GVL so that NVL_Out and NVL_In in your code are the same memory the NVL driver sends/receives.
  4. Ports and IP

    • Fill in your PLC IP and Node-RED IP. Node-RED receives on the port you set as “destination port” in the NVL Sender. Node-RED sends to the PLC IP and the port you set as “listen port” in the NVL Receiver.

4. Node-RED usage

  • Receive (PLC → Node-RED): UDP in node on the NVL Sender port (e.g. 5555). Payload is binary; see nodered-payload.md for layout and parsing.
  • Send (Node-RED → PLC): UDP out node to PLC IP and NVL Receiver port (e.g. 5556). Build the buffer from nodered-payload.md.