Living Room flow – current analysis
Analysis of the Living Room tab as pulled from Node-RED (root@10.20.30.12) on the current flows.
Tab
| Property |
Value |
| Tab id |
7de41d810b04d992 |
| Label |
Living Room |
| Nodes |
12 |
Nodes (in flow order)
1. Inputs
| Node |
Type |
Config |
Out → |
| (unnamed) |
trigger-state |
Server: 29eb84a2708d96e0. Entity: input_boolean.living_room_new. 2 outputs (allowed, blocked). |
→ HA to NVL |
| (unnamed) |
zigbee2mqtt-in |
Server: 4e20fc347c658518. Friendly name: Office Switch (TS0042). |
→ Zigbee to NVL |
2. HA → NVL path
| Node |
Type |
Role |
Out → |
| HA to NVL |
function |
ROOM_NAME = cmd_livingroom. Reads msg.topic / payload, sets ha_lN_on / ha_lN_off in flow.nvlInState.rooms.cmd_livingroom, outputs buildAndSend. |
→ NVL SEND |
3. Zigbee → NVL path
| Node |
Type |
Role |
Out → |
| Zigbee to NVL |
function |
ROOM_NAME = cmd_livingroom. Maps action (e.g. 1_single) to zigbee_swN, sets state, zigbeeClear, buildAndSend. |
→ 80ms, NVL SEND |
| 80ms |
delay |
80 ms. |
→ Clear zigbee edge |
| Clear zigbee edge |
function |
Clears zigbee_swN in state, sets buildAndSend. |
→ NVL SEND |
4. NVL send path
| Node |
Type |
Role |
Out → |
| NVL SEND |
function |
Builds payload from flow.nvlInState (roomNames with cmd_livingroom), struct_room_cmds. |
→ link out 26 |
link out 26 → (cross-tab) → Flow 1 to UDP → udp out (PLC).
5. PLC → HA sync path (in Living Room tab)
| Node |
Type |
Role |
Out → |
| link in 14 |
link in |
Receives from Flow 1 “from PLC states” link out (after nvl-receive). |
→ NVL to HA Sync |
| NVL to HA Sync |
function |
Compares PLC light state to last; outputs only on change. Output 1 = turn_on msgs, Output 2 = turn_off msgs (payload.action + payload.target.entity_id). |
→ two api-call-service nodes |
| (unnamed) |
api-call-service |
Action: input_boolean.turn_on. Entity: input_boolean.living_room_new. |
— |
| (unnamed) |
api-call-service |
Action: input_boolean.turn_off. Entity: input_boolean.living_room_new. |
— |
Flow diagram (current)
Notes
- Zigbee device in this tab is Office Switch (TS0042); commands still go to cmd_livingroom (living room NVL). If the switch is physically in the office, you may want a separate room/flow or map it to another room in Zigbee to NVL.
- NVL SEND matches the redesign: single list of rooms (
roomNames), only cmd_livingroom for now; link out 26 sends to Flow 1 → UDP.
- PLC → HA sync is in the Living Room tab: link in 14 gets PLC state from Flow 1, NVL to HA Sync outputs only on change, two api-call-service nodes with fixed
input_boolean.turn_on / input_boolean.turn_off and input_boolean.living_room_new. With “Block Input Overrides” off, the sync’s msg.payload would override; if it’s on, the fixed entity is used (which matches the single current entity).
- Flows file in the repo has been updated from this pull:
docs/integration/nodered-flows.json.