Redesign Summary - Quick Reference

What We're Changing

Current Structure → New Structure

Before:

  • Room-based with generic l_1, l_2 names
  • Fixed 6 lights per room
  • Toggle-based control
  • No status feedback from relays

After:

  • Room-based in CODESYS, flat in Home Assistant
  • Descriptive names: kitchen_main, master_bedroom_bedside_left
  • Command-based control (ON/OFF for HA, toggle for Zigbee)
  • Actual relay status feedback
  • Water boiler with comprehensive safety

Key Documents

  1. light-naming-configuration.md START HERE

    • Complete light naming for all 16 rooms
    • Water boiler control structure
    • Safety measures
    • Action: Review and modify with your actual lights
  2. redesign-implementation-roadmap.md

    • Step-by-step implementation guide
    • Phase-by-phase checklist
    • Timeline estimates
  3. structure-redesign-analysis.md

    • Detailed analysis of structure options
    • Why Option 4 (Hybrid) was chosen
  4. fb_switch-redesign-recommendation.md

    • Function block redesign details
    • Control logic improvements

Quick Structure Reference

Light Naming Convention

Format: {room}_{function}

Examples:
- kitchen_main
- master_bedroom_bedside_left
- outdoor_front_security

Function Types

  • main - Primary light
  • bedside_left/right - Bedside lamps
  • under_cabinet - Task lighting
  • security - Security lighting
  • ambient - Atmospheric lighting
  • etc.

CODESYS Access

rooms.kitchen.main.ha_on := TRUE;
rooms.master_bedroom.bedside_left.state;

Home Assistant Entity

light.kitchen_main
light.master_bedroom_bedside_left

Water Boiler Safety Features

  1. Temperature Protection (max 80°C, min 10°C)
  2. Time Limits (max 8h ON, min 30m OFF)
  3. Flow Detection (shut off if no flow)
  4. Emergency Stop (immediate shutdown)
  5. Pressure Protection (if sensor available)
  6. State Monitoring (relay status readback)
  7. Error Reporting (comprehensive error codes)

Next Steps

  1. Review light-naming-configuration.md
  2. Modify light names per room based on actual installation
  3. Map relays to lights
  4. Start Phase 1 of implementation roadmap

Status: Ready for configuration review