CODESYS Project Analysis

Overview

This document contains information extracted from the CODESYS project export file (Home_Automation.export).

Device Information

  • Device Name: codesys-home
  • CODESYS Version: 4.15.0.0
  • Platform: CODESYS Control for Raspberry Pi MC SL
  • SDK Version: 3.5.21.0
  • Order Number: 2302000009

Hardware Configuration

EtherCAT Network

  • EtherCAT Master: Version 4.9.0.0
  • EtherCAT Task: EtherCAT_Task

EtherCAT Devices

  1. EK1100 - EtherCAT Coupler (2A E-Bus)

    • Vendor: Beckhoff Automation GmbH & Co. KG
    • Order Number: EK1100
    • Function: EtherCAT coupler connecting to E-Bus modules
  2. EL1809 - 16Ch. Digital Input 24V, 3ms

    • Vendor: Beckhoff Automation GmbH & Co. KG
    • Order Number: EL1809
    • Function: 16-channel digital input module
    • Channels: 16 digital inputs (Channels 1-16)
  3. Output Module (Likely EL2004 or similar)

    • 16 output channels configured
    • Channel addresses: 16#1A00 through 16#1A0F (Channels 1-16)

Network Variables

CODESYS communicates with Node-RED using UDP-based network variables.

Variables Sent to Node-RED (NVL_Sender)

List Identifier: 1
Protocol: UDP
Task: EtherCAT_Task
Transmission: Cyclic
Interval: T#50ms
Minimum Gap: T#20ms

Structure: struct_lights containing light states for each room:

Variable Name Type Description
l_masterBedroom struct_lights Master bedroom lights
l_masterBathroom struct_lights Master bathroom lights
l_bedroom_1 struct_lights Bedroom 1 lights
l_bedroom_2 struct_lights Bedroom 2 lights
l_bathroom struct_lights Bathroom lights
l_hallway struct_lights Hallway lights
l_pantry struct_lights Pantry lights
l_kitchen struct_lights Kitchen lights
l_livingRoom struct_lights Living room lights
l_dinningRoom struct_lights Dining room lights
l_entrance struct_lights Entrance lights
l_guestWc struct_lights Guest WC lights
l_outVeranda struct_lights Outdoor veranda lights
l_outFront struct_lights Outdoor front lights
l_outSide struct_lights Outdoor side lights
l_outBack struct_lights Outdoor back lights

Variables Received from Node-RED (NVL_Receiver)

List Identifier: 3
Protocol: UDP
Task: EtherCAT_Task
Transmission: Cyclic
Interval: T#50ms
Minimum Gap: T#20ms
Import File: C:\Users\NearchosParaskeva\OneDrive - individual\Codesys_Home_Automation\NVL_Receiver.gvl

Structure: struct_switches containing switch states for each room:

Variable Name Type Description
masterBedroom struct_switches Master bedroom switches
masterBathroom struct_switches Master bathroom switches
bedroom_1 struct_switches Bedroom 1 switches
bedroom_2 struct_switches Bedroom 2 switches
bathroom struct_switches Bathroom switches
hallway struct_switches Hallway switches
pantry struct_switches Pantry switches
kitchen struct_switches Kitchen switches
livingRoom struct_switches Living room switches
dinningRoom struct_switches Dining room switches
entrance struct_switches Entrance switches
guestWc struct_switches Guest WC switches
outVeranda struct_switches Outdoor veranda switches
outFront struct_switches Outdoor front switches
outSide struct_switches Outdoor side switches
outBack struct_switches Outdoor back switches

Program Structure

Main Program (PLC_PRG)

  • Type: Program
  • Language: Structured Text (ST)
  • Function Blocks Used: fb_switch
  • Instances:
    • masterBedroom: fb_switch

Function Blocks

  • fb_toogleButton: Toggle button function block
  • fb_switch: Switch control function block

Variables Used in Logic

From the program code, the following variables are referenced:

  • lights.l_1, lights.l_2, lights.l_3, lights.l_4, lights.l_5, lights.l_6
  • switches.sw_1, switches.sw_2, switches.sw_3, switches.sw_4, switches.sw_5, switches.sw_6
  • switches.all_off
  • switches.all_on

Room Configuration

The system controls lighting for 15 rooms/areas:

  1. Master Bedroom
  2. Master Bathroom
  3. Bedroom 1
  4. Bedroom 2
  5. Bathroom
  6. Hallway
  7. Pantry
  8. Kitchen
  9. Living Room
  10. Dining Room
  11. Entrance
  12. Guest WC
  13. Outdoor Veranda
  14. Outdoor Front
  15. Outdoor Side
  16. Outdoor Back

I/O Mapping

Inputs (EL1809)

  • 16 digital input channels
  • Likely used for local switch inputs or status feedback

Outputs (16 channels, likely EL2004)

  • 16 digital output channels (16#1A00 - 16#1A0F)
  • Used to control relay outputs for lighting

Note: The exact mapping between relay outputs and rooms needs to be determined from the program logic or wiring documentation.

Libraries Used

  • IoStandard (System)
  • SM3_Basic (3S - Smart Software Solutions GmbH)
  • SM3_CNC (3S - Smart Software Solutions GmbH)
  • 3SLicense (CODESYS)
  • SM3_CamBuilder (CODESYS)
  • SM3_Robotics (CODESYS)
  • SM3_Robotics_Visu (CODESYS)
  • SM3_Transformation (CODESYS)
  • Standard (System)
  • CmpLog (System)

Task Configuration

  • EtherCAT Task: Used for EtherCAT communication and network variable updates
  • Update Rate: 50ms (cyclic transmission)

Notes

  • The project uses structured data types (struct_lights, struct_switches) for organizing room data
  • Network variables are packed and transmitted via UDP
  • The system appears to support both indoor and outdoor lighting control
  • Water boiler control mentioned in documentation was not found in the export - may be in a separate module or not yet implemented

Analysis Date: January 27, 2026
Source File: Home_Automation.export