Files
kkelomatic_home/docs/integration/nodered-flows-analysis.md
nearxos f0d883b8c2 Remove obsolete INFORMATION_NEEDED.md and streamline README.md for clarity
- Deleted the INFORMATION_NEEDED.md file as it was no longer necessary for documentation.
- Revised README.md to enhance the overview of the home automation system, focusing on how services and CODESYS connectivity work.
- Updated project structure in README.md for better organization and clarity, including links to relevant documentation.

This update simplifies the documentation and improves the overall user experience for developers and users of the home automation system.
2026-02-08 17:09:30 +02:00

3.6 KiB
Raw Permalink Blame History

Node-RED flows analysis

Flows pulled from root@10.20.30.12 (/root/.node-red/flows.json).
Snapshot: Feb 8, 2026.


Tabs (flow sheets)

Tab Purpose (from nodes)
Flow 1 CODESYS NVL (UDP), HA buttons, Room Lights subflow, dashboard links
Flow 27 (Unnamed / per-room or feature)
Living Room Living roomspecific logic → Living Room flow doc
Notifications Notifications (Telegram, etc.)
Zigbee Zigbee2MQTT in/out, MQTT
Scheduler cronplus, bigtimer, triggers

Node counts (summary)

Category Node types / count
UI 128 ui_button, 17 ui_tab, 17 ui_group, 1 ui_base
Logic 59 function, 12 change, 10 switch, 17 inject, 2 trigger, 2 delay, 2 bigtimer, 3 cronplus
Home Assistant 47 ha-entity-config, 29 ha-button, 18 ha-binary-sensor, 15 ha-device-config, 5 api-current-state, 2 api-call-service, 1 server-state-changed, 1 poll-state, 1 trigger-state, 1 ha-sensor
Zigbee 28 zigbee2mqtt-in, 9 zigbee2mqtt-out, 1 zigbee2mqtt-server, 1 zigbee2mqtt-get
CODESYS / NVL 1 nvl-send, 1 nvl-receive, 1 nvl-datatypes, 1 udp in, 1 udp out
Other 1 server (HA WebSocket), 1 mqtt-broker, 2 mqtt in, 9 http request, 2 telegram bot, 1 telegram sender, 1 telegram receiver, 43 debug, 29 link in, 29 link out
Subflows Room Lights (57bd1b149526fcee), Room filter (4dc13919bcc9d676), Subflow 1

CODESYS connectivity (Flow 1)

All NVL and UDP nodes are on tab Flow 1 (z": "46892ced77481340").

Node Role Config
udp out Send to PLC addr: 10.20.30.5, port: 1202
udp in Receive from PLC port: 1202
nvl-send Build NVL_In payload Feeds udp out. Uses node-red-contrib-nvl with inline definition (struct_switches × 15 rooms + cmd_livingroom struct_room_cmds).
nvl-receive Parse NVL_Out Triggered by udp in. Definition: 15 × struct_lights + light_livingRoom as struct_room_outs.

Notes

  • PLC IP is 10.20.30.5; Node-RED uses the same port 1202 for both sending to and receiving from the PLC (CODESYS NVL Sender and Receiver may use the same port or different; confirm in CODESYS).
  • nvl-receive uses struct_lights (6 BOOLs) for 15 rooms and struct_room_outs (6 outputs + 6 status) only for light_livingRoom. Your codesys/src/NVL docs use struct_room_outs for all rooms; the flow is a subset.
  • Room Lights subflow (Room Lights) is used from Flow 1 (and possibly Living Room) to map HA/buttons to room/light commands.

Integrations

  • Home Assistant: WebSocket server config; many ha-entity-config / ha-device-config; ha-button, ha-binary-sensor; api-current-state, api-call-service.
  • Zigbee2MQTT: One zigbee2mqtt-server; zigbee2mqtt-in (28) and zigbee2mqtt-out (9) for device events and commands.
  • MQTT: One mqtt-broker; mqtt in (2) for other topics.
  • Telegram: telegram bot (2), telegram sender, telegram receiver for notifications.
  • Dashboard: node-red-dashboard (ui_base, ui_tab, ui_group, ui_button) for a simple UI.

File location

To refresh: from the project PC run
ssh root@10.20.30.12 "cat /root/.node-red/flows.json" > docs/integration/nodered-flows.json