Issue #26 fixed in PR #40 - DynamicSymbolLoader rewritten to use text manipulation instead of sexpdata, preserving KiCAD file formatting.
204 lines
5.8 KiB
Markdown
204 lines
5.8 KiB
Markdown
# Known Issues & Workarounds
|
|
|
|
**Last Updated:** 2025-12-02
|
|
**Version:** 2.1.0-alpha
|
|
|
|
This document tracks known issues and provides workarounds where available.
|
|
|
|
---
|
|
|
|
## Current Issues
|
|
|
|
### 1. `get_board_info` KiCAD 9.0 API Issue
|
|
|
|
**Status:** KNOWN - Non-critical
|
|
|
|
**Symptoms:**
|
|
```
|
|
AttributeError: 'BOARD' object has no attribute 'LT_USER'
|
|
```
|
|
|
|
**Root Cause:** KiCAD 9.0 changed layer enumeration constants
|
|
|
|
**Workaround:** Use `get_project_info` instead for basic project details
|
|
|
|
**Impact:** Low - informational command only
|
|
|
|
---
|
|
|
|
### 2. Zone Filling via SWIG Causes Segfault
|
|
|
|
**Status:** KNOWN - Workaround available
|
|
|
|
**Symptoms:**
|
|
- Copper pours created but not filled automatically when using SWIG backend
|
|
- Calling `ZONE_FILLER` via SWIG causes segfault
|
|
|
|
**Workaround Options:**
|
|
1. Use IPC backend (zones fill correctly via IPC)
|
|
2. Open the board in KiCAD UI - zones fill automatically when opened
|
|
|
|
**Impact:** Medium - affects copper pour visualization until opened in KiCAD
|
|
|
|
---
|
|
|
|
### 3. UI Manual Reload Required (SWIG Backend)
|
|
|
|
**Status:** BY DESIGN - Fixed by IPC
|
|
|
|
**Symptoms:**
|
|
- MCP makes changes via SWIG backend
|
|
- KiCAD doesn't show changes until file is reloaded
|
|
|
|
**Current Workflow:**
|
|
```
|
|
1. MCP makes change via SWIG
|
|
2. KiCAD shows: "File has been modified. Reload? [Yes] [No]"
|
|
3. User clicks "Yes"
|
|
4. Changes appear in UI
|
|
```
|
|
|
|
**Why:** SWIG-based backend requires file I/O, can't push changes to running UI
|
|
|
|
**Fix:** Use IPC backend for real-time updates (requires KiCAD to be running with IPC enabled)
|
|
|
|
**Workaround:** Click reload prompt or use File > Revert
|
|
|
|
---
|
|
|
|
### 4. IPC Backend Experimental
|
|
|
|
**Status:** UNDER DEVELOPMENT
|
|
|
|
**Description:**
|
|
The IPC backend is currently being implemented and tested. Some commands may not work as expected in all scenarios.
|
|
|
|
**Known IPC Limitations:**
|
|
- KiCAD must be running with IPC enabled
|
|
- Some commands fall back to SWIG (e.g., delete_trace)
|
|
- Footprint loading uses hybrid approach (SWIG for library, IPC for placement)
|
|
- Error handling may not be comprehensive in all cases
|
|
|
|
**Workaround:** If IPC fails, the server automatically falls back to SWIG backend
|
|
|
|
---
|
|
|
|
---
|
|
|
|
## Recently Fixed
|
|
|
|
### Schematic Component Corruption (Fixed 2026-02-26)
|
|
|
|
**Was:** `add_schematic_component` corrupted .kicad_sch files due to sexpdata formatting issues
|
|
**Now:** Rewritten to use text manipulation, preserves KiCAD file formatting perfectly
|
|
**Impact:** Schematic workflow fully functional with all component types
|
|
**Fixed in:** PR #40, commit a69d288
|
|
|
|
### DRC Violations API KiCAD 9.0 (Fixed 2026-02-26)
|
|
|
|
**Was:** `get_drc_violations` failed with `AttributeError: 'BOARD' object has no attribute 'GetDRCMarkers'`
|
|
**Now:** Reimplemented to use `run_drc()` internally which calls kicad-cli
|
|
**Impact:** Maintains backward compatibility while using stable kicad-cli interface
|
|
|
|
### Component Library Integration (Fixed 2025-11-01)
|
|
|
|
**Was:** Could not find footprint libraries
|
|
**Now:** Auto-discovers 153 KiCAD footprint libraries, search and list working
|
|
|
|
### Routing Operations KiCAD 9.0 (Fixed 2025-11-01)
|
|
|
|
**Was:** Multiple API compatibility issues with KiCAD 9.0
|
|
**Now:** All routing commands tested and working:
|
|
- `netinfo.FindNet()` -> `netinfo.NetsByName()[name]`
|
|
- `zone.SetPriority()` -> `zone.SetAssignedPriority()`
|
|
- `ZONE_FILL_MODE_POLYGON` -> `ZONE_FILL_MODE_POLYGONS`
|
|
|
|
### KiCAD Process Detection (Fixed 2025-10-26)
|
|
|
|
**Was:** `check_kicad_ui` detected MCP server's own processes
|
|
**Now:** Properly filters to only detect actual KiCAD binaries
|
|
|
|
### set_board_size KiCAD 9.0 (Fixed 2025-10-26)
|
|
|
|
**Was:** Failed with `BOX2I_SetSize` type error
|
|
**Now:** Works with KiCAD 9.0 API
|
|
|
|
### add_board_text KiCAD 9.0 (Fixed 2025-10-26)
|
|
|
|
**Was:** Failed with `EDA_ANGLE` type error
|
|
**Now:** Works with KiCAD 9.0 API
|
|
|
|
### Schematic Parameter Mismatch (Fixed 2025-12-02)
|
|
|
|
**Was:** `create_schematic` failed due to parameter name differences between TypeScript and Python
|
|
**Now:** Accepts multiple parameter naming conventions (`name`, `projectName`, `title`, `filename`)
|
|
|
|
---
|
|
|
|
## Reporting New Issues
|
|
|
|
If you encounter an issue not listed here:
|
|
|
|
1. **Check MCP logs:** `~/.kicad-mcp/logs/kicad_interface.log`
|
|
2. **Check KiCAD version:** `python3 -c "import pcbnew; print(pcbnew.GetBuildVersion())"` (must be 9.0+)
|
|
3. **Try the operation in KiCAD directly** - is it a KiCAD issue?
|
|
4. **Open GitHub issue** with:
|
|
- Error message
|
|
- Log excerpt
|
|
- Steps to reproduce
|
|
- KiCAD version
|
|
- OS and version
|
|
|
|
---
|
|
|
|
## Priority Matrix
|
|
|
|
| Issue | Priority | Impact | Status |
|
|
|-------|----------|--------|--------|
|
|
| IPC Backend Testing | High | Medium | In Progress |
|
|
| get_board_info Fix | Low | Low | Known |
|
|
| Zone Filling (SWIG) | Medium | Medium | Workaround Available |
|
|
| Schematic Support | Medium | Medium | Partial |
|
|
|
|
---
|
|
|
|
## General Workarounds
|
|
|
|
### Server Won't Start
|
|
```bash
|
|
# Check Python can import pcbnew
|
|
python3 -c "import pcbnew; print(pcbnew.GetBuildVersion())"
|
|
|
|
# Check paths
|
|
python3 python/utils/platform_helper.py
|
|
```
|
|
|
|
### Commands Fail After Server Restart
|
|
```
|
|
# Board reference is lost on restart
|
|
# Always run open_project after server restart
|
|
```
|
|
|
|
### KiCAD UI Doesn't Show Changes (SWIG Mode)
|
|
```
|
|
# File > Revert (or click reload prompt)
|
|
# Or: Close and reopen file in KiCAD
|
|
# Or: Use IPC backend for automatic updates
|
|
```
|
|
|
|
### IPC Not Connecting
|
|
```
|
|
# Ensure KiCAD is running
|
|
# Enable IPC: Preferences > Plugins > Enable IPC API Server
|
|
# Have a board open in PCB editor
|
|
# Check socket exists: ls /tmp/kicad/api.sock
|
|
```
|
|
|
|
---
|
|
|
|
**Need Help?**
|
|
- Check [IPC_BACKEND_STATUS.md](IPC_BACKEND_STATUS.md) for IPC details
|
|
- Check [REALTIME_WORKFLOW.md](REALTIME_WORKFLOW.md) for workflow tips
|
|
- Check logs: `~/.kicad-mcp/logs/kicad_interface.log`
|
|
- Open an issue on GitHub
|