New tools - datasheet:
- get_datasheet_url: construct LCSC datasheet PDF URL + product page URL
without any API key (URL schema: https://www.lcsc.com/datasheet/<C#>.pdf)
- enrich_datasheets: scan .kicad_sch, write LCSC datasheet URL into every
symbol that has an LCSC property but an empty Datasheet field; supports
dry_run=true for preview; text-based implementation (no skip writes)
Implementation: python/commands/datasheet_manager.py
New tool - schematic:
- delete_schematic_component: remove a placed symbol from a .kicad_sch file
by reference designator (e.g. R1, U3)
Bug fix - delete_schematic_component (two separate root causes):
1. No MCP tool named delete_schematic_component was registered at all.
Any delete-symbol request fell through to the PCB-only delete_component
tool which searches pcbnew.BOARD and always returned 'Component not found'
for schematic symbols.
2. component_schematic.py::remove_component() still used skip for writes.
PR #40 rewrote DynamicSymbolLoader (add path) to avoid skip-induced
schematic corruption, but the delete path was not touched by that PR.
Fix: _handle_delete_schematic_component in kicad_interface.py uses direct
text manipulation with parenthesis-depth tracking (same technique as PR #40),
bypassing component_schematic.py entirely. Error message explicitly guides
users: 'use delete_component for PCB footprints'.
Files changed:
- python/commands/datasheet_manager.py (new)
- src/tools/datasheet.ts (new)
- python/kicad_interface.py: 3 new handlers + dispatch entries
- src/tools/schematic.ts: delete_schematic_component tool
- src/server.ts: registerDatasheetTools import + call
- src/tools/index.ts: export registerDatasheetTools
- CHANGELOG.md: document all above
- connection_schematic.py: generate_netlist() now accepts schematic_path param,
threaded through to get_net_connections() so PinLocator is actually invoked
(previously only 1 connection per component was returned due to fallback break)
- kicad_interface.py: pass schematic_path to generate_netlist()
- pin_locator.py: add _schematic_cache to avoid loading Schematic() once per pin
(was causing timeout: O(nets x components x pins) Schematic() calls)
- server.ts: remove fragile PYTHONPATH?.includes('KiCad') condition,
always prefer KiCAD bundled Python on Windows when executable exists
- CHANGELOG.md: document fixes under v2.2.0-alpha
Comprehensive documentation of Phase 2 achievements including power symbol support, wire graph analysis for net connectivity, critical bug fixes (template mapping, special character handling), and 100% passing integration tests. Removes emoji per style guidelines.
Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>
Documentation Updates:
- README: Updated Schematic Design section from 6 to 9 tools
- Added "Wiring & Connections" subsection highlighting new capabilities
- Documented automatic pin discovery with rotation support
- Listed smart routing options (direct, orthogonal)
- Added net label management features
- CHANGELOG: Added Phase 1 wiring system entry with complete feature list
New Features Documented:
- add_schematic_connection with auto pin discovery
- add_schematic_net_label with orientation control
- WireManager and PinLocator implementation
- S-expression precision and format compliance
Part of Issue #26 schematic wiring implementation
Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>