feat: datasheet tools + fix missing delete_schematic_component
New tools - datasheet: - get_datasheet_url: construct LCSC datasheet PDF URL + product page URL without any API key (URL schema: https://www.lcsc.com/datasheet/<C#>.pdf) - enrich_datasheets: scan .kicad_sch, write LCSC datasheet URL into every symbol that has an LCSC property but an empty Datasheet field; supports dry_run=true for preview; text-based implementation (no skip writes) Implementation: python/commands/datasheet_manager.py New tool - schematic: - delete_schematic_component: remove a placed symbol from a .kicad_sch file by reference designator (e.g. R1, U3) Bug fix - delete_schematic_component (two separate root causes): 1. No MCP tool named delete_schematic_component was registered at all. Any delete-symbol request fell through to the PCB-only delete_component tool which searches pcbnew.BOARD and always returned 'Component not found' for schematic symbols. 2. component_schematic.py::remove_component() still used skip for writes. PR #40 rewrote DynamicSymbolLoader (add path) to avoid skip-induced schematic corruption, but the delete path was not touched by that PR. Fix: _handle_delete_schematic_component in kicad_interface.py uses direct text manipulation with parenthesis-depth tracking (same technique as PR #40), bypassing component_schematic.py entirely. Error message explicitly guides users: 'use delete_component for PCB footprints'. Files changed: - python/commands/datasheet_manager.py (new) - src/tools/datasheet.ts (new) - python/kicad_interface.py: 3 new handlers + dispatch entries - src/tools/schematic.ts: delete_schematic_component tool - src/server.ts: registerDatasheetTools import + call - src/tools/index.ts: export registerDatasheetTools - CHANGELOG.md: document all above
This commit is contained in:
39
CHANGELOG.md
39
CHANGELOG.md
@@ -36,6 +36,45 @@ All notable changes to the KiCAD MCP Server project are documented here.
|
||||
- `library.py`: Fix loop variable shadowing `Path` object (mypy)
|
||||
- `design_rules.py`: Add type annotation for `violation_counts` (mypy)
|
||||
|
||||
### Pending additions (not yet committed)
|
||||
|
||||
**Datasheet tools:**
|
||||
- `get_datasheet_url` - Return LCSC datasheet PDF URL and product page URL for a given
|
||||
LCSC number (e.g. `C179739` → `https://www.lcsc.com/datasheet/C179739.pdf`).
|
||||
No API key required – URL is constructed directly from the LCSC number.
|
||||
- `enrich_datasheets` - Scan a `.kicad_sch` file and write LCSC datasheet URLs into
|
||||
every symbol that has an `LCSC` property but an empty `Datasheet` field. After
|
||||
enrichment the URL appears natively in KiCAD's symbol properties, footprint browser
|
||||
and any other tool that reads the standard KiCAD `Datasheet` field.
|
||||
Supports `dry_run=true` for preview without writing.
|
||||
Implementation: `python/commands/datasheet_manager.py` (text-based, no `skip` writes)
|
||||
|
||||
**Schematic tools:**
|
||||
- `delete_schematic_component` - Remove a placed symbol from a `.kicad_sch` file by
|
||||
reference designator (e.g. `R1`, `U3`).
|
||||
|
||||
### Bug Fixes (pending)
|
||||
|
||||
- `schematic.ts` / `kicad_interface.py`: Fix missing `delete_schematic_component` MCP tool.
|
||||
|
||||
**Root cause (two separate issues):**
|
||||
1. No MCP tool named `delete_schematic_component` existed. Claude had no way to call
|
||||
it, so any "delete schematic component" request fell through to the PCB-only
|
||||
`delete_component` tool, which searches `pcbnew.BOARD` and always returned
|
||||
"Component not found" for schematic symbols.
|
||||
2. `component_schematic.py::remove_component()` still used `skip` for writes.
|
||||
PR #40 rewrote `DynamicSymbolLoader` (add path) to avoid `skip`-induced schematic
|
||||
corruption, but `remove_component` (delete path) was not touched by that PR.
|
||||
|
||||
**Fix:**
|
||||
- Added `delete_schematic_component` to the TypeScript tool layer (`schematic.ts`)
|
||||
with clear docstring distinguishing it from the PCB `delete_component`.
|
||||
- Implemented `_handle_delete_schematic_component` in `kicad_interface.py` using
|
||||
direct text manipulation (parenthesis-depth tracking, same approach as PR #40).
|
||||
Does not call `component_schematic.py::remove_component()` at all.
|
||||
- Error message explicitly guides the user when the wrong tool is used:
|
||||
*"note: this tool removes schematic symbols, use delete_component for PCB footprints"*
|
||||
|
||||
### Pending fixes (not yet committed)
|
||||
|
||||
- `connection_schematic.py` / `kicad_interface.py`: Fix `generate_netlist` missing
|
||||
|
||||
Reference in New Issue