<message>Add new documentation files for device DNS management via DHCP and dnsmasq configuration. Update cloud-init scripts to ensure proper handling of /etc/resolv.conf and DNS settings, allowing for seamless integration with file.server. Modify existing scripts to support dynamic LAN subnet configuration and improve overall network boot functionality. These changes enhance user experience and streamline the setup process for the CM4 eMMC provisioning service.
This commit is contained in:
63
emmc-provisioning/docs/PROXMOX-HOST-COMPARISON.md
Normal file
63
emmc-provisioning/docs/PROXMOX-HOST-COMPARISON.md
Normal file
@@ -0,0 +1,63 @@
|
||||
# Proxmox host comparison: working vs new
|
||||
|
||||
Quick reference from comparing **working** (10.130.60.224) and **new** (100.106.128.36) Proxmox hosts.
|
||||
|
||||
## Same on both
|
||||
|
||||
| Item | Status |
|
||||
|------|--------|
|
||||
| `/opt/cm4-provisioning/env` | Same (GOLDEN_IMAGE, RPIBOOT_DIR, EMMC_SIZE_BYTES=8589934592, SHRINK_BACKUP, etc.) |
|
||||
| `/etc/cm4-provisioning/enabled` | Present (provisioning enabled) |
|
||||
| udev rules `89-cm4-boot-mode-permissions.rules` | Same (MODE="0666" for 2b8e, 0a5c:2711) |
|
||||
| udev rules `90-cm4-boot-mode.rules` | Same (trigger cm4-flash-trigger.sh on add) |
|
||||
| `/usr/local/bin/cm4-flash-trigger.sh` | Same (starts cm4-flash.service) |
|
||||
| `cm4-flash.service` | Same (ExecStartPre=sleep 5, TimeoutStartSec=7200) |
|
||||
| `cm4-build-cloudinit.path`, `cm4-shrink.path` + services | Same |
|
||||
| `build-cloudinit-image.sh`, `run-shrink-on-host.sh`, `fix-gadget-bootcode-on-host.sh` | Same (md5 match) |
|
||||
|
||||
## Differences
|
||||
|
||||
### 1. `/opt/usbboot/mass-storage-gadget64/bootcode4.bin` — **fixed**
|
||||
|
||||
- **Working:** Present (105984 bytes). rpiboot needs this or it prints "No 'bootcode' files found".
|
||||
- **New:** Was missing; fixed by copying from working host. Verify: `ls -la /opt/usbboot/mass-storage-gadget64/bootcode4.bin` on new.
|
||||
|
||||
### 2. `/opt/cm4-provisioning/flash-emmc-on-connect.sh`
|
||||
|
||||
- **Working:** Older version (14421 bytes, md5 `dbac0bc2...`).
|
||||
- **New:** Newer version (15449 bytes, md5 `6081bda7...`) with longer device wait (60s/90s), relaxed size check (50–120%), and extra diagnostics on "No suitable block device".
|
||||
|
||||
**Recommendation:** Copy the repo script to the **working** host so both use the same version:
|
||||
|
||||
```bash
|
||||
scp emmc-provisioning/host/flash-emmc-on-connect.sh root@10.130.60.224:/opt/cm4-provisioning/
|
||||
```
|
||||
|
||||
### 3. `/var/lib/cm4-provisioning/golden.img`
|
||||
|
||||
- **Working:** Present (symlink to a backup image). Required for **Deploy** (writing image to device).
|
||||
- **New:** Missing. Backup works; Deploy will show "Golden image not found" until you set one (dashboard “Set as golden” or `scp` an image to the host as `golden.img`).
|
||||
|
||||
### 4. `/opt/cm4-provisioning/dashboard/` (host only)
|
||||
|
||||
- **Working:** Directory exists (owner 1000:1000). Dashboard normally runs in the **LXC**, so this may be leftover or unused on the host.
|
||||
- **New:** No dashboard dir on host. No action needed unless you run the dashboard on the host.
|
||||
|
||||
### 5. Extra files in `/var/lib/cm4-provisioning/` on working
|
||||
|
||||
- **Working:** `build_cloudinit_status.json`, `cloudinit_templates.json`, `first_boot_status.json` (written by dashboard/LXC when using cloud-init build).
|
||||
- **New:** Not present yet. They appear when you use the dashboard from the LXC; not required for flash/backup.
|
||||
|
||||
## Checklist for new host (100.106.128.36)
|
||||
|
||||
- [x] `bootcode4.bin` in `/opt/usbboot/mass-storage-gadget64/` (copied from working)
|
||||
- [x] Same udev rules, trigger, and systemd units
|
||||
- [x] Same env. `EMMC_SIZE_BYTES` is optional; device detection is dynamic (any new block device after rpiboot is accepted for 8/16/32 GB CM4).
|
||||
- [ ] Set `golden.img` for Deploy (copy image or use dashboard “Set as golden” from a backup)
|
||||
- [x] `flash-emmc-on-connect.sh` is the updated version (longer wait, diagnostics)
|
||||
|
||||
## If flash still fails on new host
|
||||
|
||||
1. Check flash.log: `ssh root@100.106.128.36 'tail -80 /var/lib/cm4-provisioning/flash.log'` — the script now logs "Current block devices" and sizes when no device is found.
|
||||
2. Ensure eMMC disable jumper is set and you use the USB slave port; unplug and replug.
|
||||
3. Optional: increase udev/systemd delay (e.g. `ExecStartPre=/bin/sleep 10` in `cm4-flash.service`) if the device is slow to enumerate.
|
||||