Remove obsolete INFORMATION_NEEDED.md and streamline README.md for clarity
- Deleted the INFORMATION_NEEDED.md file as it was no longer necessary for documentation. - Revised README.md to enhance the overview of the home automation system, focusing on how services and CODESYS connectivity work. - Updated project structure in README.md for better organization and clarity, including links to relevant documentation. This update simplifies the documentation and improves the overall user experience for developers and users of the home automation system.
This commit is contained in:
31
docs/integration/ha-to-nvl-function.js
Normal file
31
docs/integration/ha-to-nvl-function.js
Normal file
@@ -0,0 +1,31 @@
|
||||
// Writes to state.rooms.cmd_livingroom (NVL variable cmd_livingroom).
|
||||
const ROOM_NAME = 'cmd_livingroom';
|
||||
const entityId = (msg.topic || '').toString();
|
||||
const parts = entityId.split('_');
|
||||
const last = parts[parts.length - 1] || '';
|
||||
const num = parseInt(last, 10);
|
||||
const lightNum = (!isNaN(num) && num >= 1) ? Math.min(6, num) : 1;
|
||||
|
||||
// Normalize state: HA / trigger-state can send payload as string, object with .state, or data.new_state.state
|
||||
let rawState = msg.payload;
|
||||
if (rawState !== null && typeof rawState === 'object' && rawState.state !== undefined) rawState = rawState.state;
|
||||
if (msg.data && msg.data.new_state && msg.data.new_state.state !== undefined) rawState = msg.data.new_state.state;
|
||||
const isOn = (rawState === 'on' || rawState === true);
|
||||
|
||||
node.warn('[HA to NVL] topic=' + entityId + ' rawState=' + JSON.stringify(rawState) + ' → lightNum=' + lightNum + ' isOn=' + isOn);
|
||||
|
||||
if (!flow.get('nvlInState')) flow.set('nvlInState', { rooms: {}, boiler: {} });
|
||||
const state = flow.get('nvlInState');
|
||||
if (!state.rooms[ROOM_NAME]) state.rooms[ROOM_NAME] = {};
|
||||
const r = state.rooms[ROOM_NAME];
|
||||
r['ha_l' + lightNum + '_on'] = false;
|
||||
r['ha_l' + lightNum + '_off'] = false;
|
||||
if (isOn) r['ha_l' + lightNum + '_on'] = true;
|
||||
else r['ha_l' + lightNum + '_off'] = true;
|
||||
flow.set('nvlInState', state);
|
||||
|
||||
node.warn('[HA to NVL] set cmd_livingroom ha_l' + lightNum + '_' + (isOn ? 'on' : 'off') + '=true, buildAndSend');
|
||||
|
||||
// PLC uses R_TRIG (rising edge). If "off" still doesn’t work, add a flow: after this node, 80ms delay then clear ha_l*_off and buildAndSend again (pulse).
|
||||
msg.payload = { buildAndSend: true };
|
||||
return msg;
|
||||
Reference in New Issue