Bug 1 - add_schematic_component: footprint parameter silently ignored
The footprint value from MCP params was never passed through to
DynamicSymbolLoader.add_component() / create_component_instance().
Every placed symbol had an empty Footprint field regardless of input.
Fix: added footprint: str='' to both functions, passed through all
call sites, added footprint to schematic.ts tool schema.
Bug 2 - delete_schematic_component: only deleted first duplicate
When a reference appeared multiple times (e.g. after a failed
add attempt), only the first instance was removed due to break
after first match. Fix: collect all matching blocks first, then
delete back-to-front to preserve indices. Response now includes
deleted_count.
New tool - edit_schematic_component
Update footprint, value or reference of a placed symbol in-place.
More efficient than delete+re-add: preserves position and UUID.
Accepts: schematicPath, reference, footprint?, value?, newReference?
All 3 fixes verified by live tests on a real JLCPCB/KiCAD 9 project:
- R_TEST1: footprint Resistor_SMD:R_0603_1608Metric written correctly
- J1 duplicate: deleted_count=2 with single call
- J2 edit: PinSocket footprint assigned in-place, no delete+add needed
- PCB update (F8) confirmed: only components with footprint imported