Implements advanced trace manipulation and routing pattern copying:
- Enhanced delete_trace with net-based bulk deletion and layer filtering
- Added modify_trace to change width, layer, or net by UUID/position
- Added copy_routing_pattern to replicate routing between component groups
Co-Authored-By: Claude Opus 4.5 <noreply@anthropic.com>
Issue #32 - Unknown command errors:
- Register get_board_extents in command_routes (was implemented but not registered)
- Implement find_component command with pattern matching on reference/value/footprint
- Add schemas for both commands
Issue #30 - PCB routing replication (Phase 1):
- Implement get_component_pads: returns all pads with positions, nets, shapes
- Implement get_pad_position: returns specific pad coordinates and properties
- Implement query_traces: query traces by net, layer, or bounding box
- Add schemas for all new commands
Issue #26 - Schematic workflow:
- Add missing schemas for add_schematic_connection, add_schematic_net_label,
connect_to_net, get_net_connections, and generate_netlist
Issue #19 - macOS Python path detection:
- Add Python 3.13 to version detection
- Add alternative KiCAD installation paths (user Applications, capitalization variants)
- Add Homebrew Python fallback paths for Apple Silicon and Intel Macs
- Expand platform_helper.py with same improvements
Co-Authored-By: Claude Opus 4.5 <noreply@anthropic.com>
Updates MCP handlers to use the new wiring infrastructure:
Handler Updates:
- _handle_add_schematic_wire: Uses WireManager.add_wire() with S-expression manipulation
- _handle_add_schematic_connection: Uses ConnectionManager with automatic pin discovery and routing options (direct, orthogonal_h, orthogonal_v)
- _handle_add_schematic_net_label: Uses WireManager.add_label() with support for label types and orientation
Features:
- Automatic pin location discovery with rotation support
- Professional wire routing (direct, orthogonal horizontal-first, orthogonal vertical-first)
- Net label placement with customizable types (label, global_label, hierarchical_label)
- Comprehensive error handling and logging
Testing:
- All MCP handlers tested and verified working
- Integration test: 100% passing (2 wires, 1 label created successfully)
- Verified with kicad-skip that wires and labels are correctly formed
Part of Issue #26 schematic wiring implementation (Phase 1)
Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>
MAJOR MILESTONE: Dynamic symbol loading is now fully integrated through the MCP interface!
## What's Working
✅ **Full MCP Integration**
- Modified _handle_add_schematic_component to orchestrate dynamic loading
- Detects when symbols need dynamic loading (not in static templates)
- Automatically saves → injects → reloads → clones → saves workflow
✅ **ComponentManager Integration**
- Added schematic_path parameter to add_component() and get_or_create_template()
- Seamlessly switches between static templates and dynamic loading
- Proper error handling and fallback mechanisms
✅ **Smart Detection**
- Checks if component type is in static template map
- Verifies template exists in current schematic
- Only triggers dynamic loading when truly needed
✅ **Reload Orchestration**
- Saves schematic before dynamic loading (preserves changes)
- Calls DynamicSymbolLoader.load_symbol_dynamically()
- Reloads schematic to get newly injected symbols
- Clones from reloaded templates
## Test Results
End-to-end integration test: ✅ **100% PASSING**
Components tested:
- R (resistor) - static template, dynamically loaded
- C (capacitor) - static template, dynamically loaded
- Battery - pure dynamic loading ✨
- Fuse - pure dynamic loading ✨
- Transformer_1P_1S - pure dynamic loading ✨
All 5 components added successfully!
## Impact
Users can now add **ANY symbol from KiCad's ~10,000 symbol libraries** through the MCP interface!
No more limitation to 13 pre-configured templates!
## Technical Details
1. MCP handler detects dynamic loading need
2. Saves current schematic state
3. Calls dynamic loader (injects symbol + creates template)
4. Reloads schematic (kicad-skip sees new template)
5. Clones template to create component
6. Saves final result
Response includes:
- success status
- dynamic_loading_used flag
- symbol_source (library:symbol)
- template_reference
## Files Modified
- python/kicad_interface.py: _handle_add_schematic_component - full orchestration
- python/commands/component_schematic.py: add_component() and get_or_create_template() - schematic_path support
## Time Estimate vs Actual
Estimated: 2-3 hours
Actual: ~2 hours
Status: ✅ ON TARGET!
Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>
Implements full JLCPCB parts catalog integration alongside existing local library search,
giving users two complementary approaches for component selection:
1. Local Symbol Libraries (PR #25)
- Search JLCPCB libraries installed via KiCad PCM
- Pre-configured symbols with footprints
- Works offline, no API needed
2. JLCPCB API Integration (NEW)
- Complete 100k+ parts catalog access
- Real-time pricing and stock information
- Basic/Extended library type identification
- Cost optimization and alternative suggestions
- Package-to-footprint mapping
New Features:
- download_jlcpcb_database: Download complete parts catalog to local SQLite DB
- search_jlcpcb_parts: Parametric search with pricing, stock, library type filters
- get_jlcpcb_part: Detailed part info with price breaks and footprint suggestions
- get_jlcpcb_database_stats: Database statistics and status
- suggest_jlcpcb_alternatives: Find cheaper/available alternatives
Implementation:
- Python API client (commands/jlcpcb.py) - JLCPCB API authentication and data fetching
- Parts database manager (commands/jlcpcb_parts.py) - SQLite storage and search
- TypeScript MCP tools (tools/jlcpcb-api.ts) - User-facing tool definitions
- Comprehensive documentation (docs/JLCPCB_USAGE_GUIDE.md)
Database Features:
- ~100k parts with descriptions, pricing, stock levels
- Full-text search on descriptions and part numbers
- Parametric filtering (category, package, manufacturer, library type)
- Package-to-footprint mapping for KiCad
- Intelligent alternative suggestions
Setup Requirements:
- JLCPCB_API_KEY and JLCPCB_API_SECRET environment variables
- One-time database download (~5-10 minutes, 42MB)
- requests library (already in requirements.txt)
Benefits:
- Cost optimization (identify Basic parts = free assembly)
- Real-time stock checking
- Complete catalog access
- Works offline after initial download
- Complements local library search
🤖 Generated with [Claude Code](https://claude.com/claude-code)
Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>
Adds comprehensive local KiCad symbol library search functionality and fixes KICAD9_3RD_PARTY environment variable resolution.
Features:
- Symbol library search by name, LCSC ID, description, manufacturer, MPN
- Support for 3rd party libraries installed via Plugin and Content Manager
- New MCP tools: search_symbols, list_symbol_libraries, get_symbol_info
- Enhanced library path resolution for KiCad 8 and 9
This enables users with locally installed JLCPCB libraries to search and use components directly.
Co-authored-by: l3wi <l3wi@users.noreply.github.com>
Add KiCAD IPC API backend using kicad-python library for real-time
communication with KiCAD 9.0+. Changes now appear instantly in KiCAD
UI without manual reload.
Key changes:
- Implement IPCBackend and IPCBoardAPI classes for IPC communication
- Auto-detect IPC availability and fall back to SWIG when unavailable
- Route existing commands (route_trace, add_via, place_component, etc.)
through IPC automatically when available
- Add transaction support for proper undo/redo
- Add socket path auto-detection for Linux (/tmp/kicad/api.sock)
New commands:
- get_backend_info: Check which backend is active
Supported IPC operations:
- Board: set_size, get_board_info, save
- Routing: route_trace, add_via, add_net
- Components: place, move, delete, list
- Text: add_text, add_board_text
SWIG backend is now deprecated and will be removed when KiCAD 10.0
drops SWIG support.
Requires: kicad-python>=0.5.0, KiCAD 9.0+ with IPC enabled
🤖 Generated with [Claude Code](https://claude.com/claude-code)
Co-Authored-By: Claude <noreply@anthropic.com>
Major improvements to schematic editing capabilities:
## Python Implementation (connection_schematic.py)
- Implemented pin-to-pin connection logic using kicad-skip
- Added get_pin_location() to find absolute pin positions
- Implemented add_connection() for wire connections between component pins
- Added add_net_label() for creating net labels
- Added connect_to_net() to connect pins to named nets
- Implemented get_net_connections() to query net connectivity
- Added generate_netlist() for schematic netlist extraction
## MCP Handlers (kicad_interface.py)
- Added 5 new command handlers:
- add_schematic_connection - Pin-to-pin wiring
- add_schematic_net_label - Net label placement
- connect_to_net - Connect pin to named net
- get_net_connections - Query net connectivity
- generate_netlist - Export netlist data
## TypeScript Tools (schematic.ts)
- Added 5 new MCP tools with proper schemas and validation
- Enhanced user feedback with descriptive messages
- Total schematic tools increased from 3 to 8
## Features
- Pin location calculation with symbol rotation support
- Automatic wire stub creation for net labels
- Comprehensive netlist generation with component and net info
- Full logging for debugging connection issues
This resolves the schematic editing limitations and enables users to:
- Wire component pins together directly
- Use net labels for cleaner schematics
- Query schematic connectivity
- Generate netlists for manufacturing
🤖 Generated with Claude Code
Co-Authored-By: Claude <noreply@anthropic.com>
This commit fixes Windows Claude Desktop compatibility by implementing
proper MCP JSON-RPC 2.0 protocol handling in the Python interface.
Changes:
- Added JSON-RPC 2.0 message detection and handling
- Implemented MCP protocol methods: initialize, tools/list, tools/call
- Maintained backwards compatibility with legacy custom format
- Removed accidentally included typescript-sdk directory
Fixes#5 - Claude Desktop not working on Windows
Credit to @spplecxer for identifying the issue and providing the fix.
🤖 Generated with [Claude Code](https://claude.com/claude-code)
Co-Authored-By: Claude <noreply@anthropic.com>
- Added comprehensive documentation (BUILD_AND_TEST, CLIENT_CONFIG, KNOWN_ISSUES, ROADMAP, etc.)
- Updated core functionality for board outline, size, and utilities
- Added new tools for project, routing, schematic, and UI management
- Included TypeScript SDK with full MCP implementation
- Updated configuration examples for all platforms
- Added changelog and status tracking
- Improved Python utilities with KiCAD process management
- Enhanced resource helpers and server capabilities
🤖 Generated with [Claude Code](https://claude.com/claude-code)
Co-Authored-By: Claude <noreply@anthropic.com>