Upstream added `from annotations import AnnotationLoader` and moved
`from commands.wire_manager import WireManager` to module-level in
kicad_interface.py. The smoke test now stubs annotations and ensures
python/ is on sys.path so commands.* imports resolve without installing.
Previously the handler used kicad-skip to apply rotation and mirror.
kicad-skip has no API for (mirror x/y) on placed symbols, causing:
'NoneType' object has no attribute 'value'
Fix:
- Rewrote _handle_rotate_schematic_component to use sexpdata (same
approach as move_schematic_component) for both rotation and mirror
- Added WireDragger.compute_pin_positions_for_rotation: computes old
and new pin world positions when rotation/mirror changes at fixed (x,y)
- Added WireDragger.update_symbol_rotation_mirror: updates (at) rotation
and adds/removes/replaces the (mirror x/y) sexpdata token cleanly
- Connected wires now follow pin positions after rotate/mirror via the
existing WireDragger.drag_wires infrastructure
Tests: 10 unit tests in tests/test_rotate_schematic_mirror.py covering
update_symbol_rotation_mirror, compute_pin_positions_for_rotation, and
a handler smoke test.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Replaces the manual add_schematic_junction tool with automatic junction
management. WireManager.sync_junctions inserts/removes junction dots
based on wire endpoints plus component pin positions and is invoked
after add_wire, add_polyline_wire, delete_wire, move, and rotate.
- Pin-aware: parses lib_symbols and applies KiCad's mirror/rotate/
translate transform to compute world pin coordinates
- Multi-unit safe: filters lib_symbols sub-units by the placed
symbol's (unit N) field plus the unit-0 common body
- Removes the now-unused WireManager.add_junction static method
- Updates CHANGELOG [Unreleased] with the tool removal notice
- Adds .mcp.json to .gitignore (machine-local paths)
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
The symbol-to-schematic y-flip was applied twice in sequence (two identical
negation blocks with matching comments), cancelling out and leaving pin
Y-coordinates mirrored about the placement Y. For symmetric passives the
bug is invisible (pin 1 and pin 2 are electrically interchangeable); for
ICs with non-equivalent pins (power pins, opamp inputs, etc.) this causes
tools that go through PinLocator — connect_to_net, add_schematic_connection,
add_schematic_net_label with componentRef+pinNumber — to place connections
at the mirror-flipped pin. Verified against kicad-cli generate_netlist
ground truth: on a Device:R placed at (111.76, 83.82), pin 1 resolves to
y=80.01 (actual) vs y=87.63 (pre-fix).
This is a regression of PR #103, which originally fixed the y-negation;
the redundant second block was added subsequently.
Includes a regression test with both a straight Device:R and a rotated
Device:C to exercise the y-flip + rotation pipeline.
KiCad serialises rescued or locally-customised library entries with an
extra (lib_name "...") child before (lib_id "..."):
(symbol
(lib_name "RESISTOR_0603_4")
(lib_id "MF_Passives:RESISTOR_0603")
(at 132.08 44.45 90)
...)
The block-matching regex in _handle_get_schematic_component,
_handle_edit_schematic_component, and _handle_delete_schematic_component
required (lib_id IMMEDIATELY after (symbol, so any placed component
using this form was silently invisible to lookup. The user-visible
symptom is "Component '<ref>' not found in schematic" even though the
component is plainly present (and reachable through list / IPC paths).
This bug also affected set/remove_schematic_component_property and the
existing footprint/value/reference rewriting paths in edit, since they
all share the same lookup code.
The parent-position lookup used a similarly-strict regex
((symbol (lib_id "...") (at ...))), which silently fell back to (0,0)
on (lib_name)-first symbols and caused new properties added through
the custom-properties path to anchor at the schematic origin instead
of the parent symbol.
Fix: relax the symbol-block opening pattern to (symbol\s+\( — matching
any opening paren after (symbol — and read the symbol's origin from
the first (at ...) inside the block. Library-definition entries inside
(lib_symbols ...) are still excluded by the existing range check
(they use the (symbol "name" ...) form with a quoted string, not a
paren).
Adds 7 regression tests in TestLibNameBeforeLibIdOrdering using a
real-world (lib_name)-first resistor block, covering get / edit /
set-property / remove-property / delete and verifying that newly
added properties anchor to the symbol origin instead of (0, 0).
Promotes BOM / sourcing fields (MPN, Manufacturer, DigiKey_PN, LCSC,
JLCPCB_PN, Voltage, Tolerance, Dielectric, ...) to first-class citizens
on placed schematic symbols.
New MCP tools:
- set_schematic_component_property: add or update one custom property
on a component (convenience wrapper around edit_schematic_component).
- remove_schematic_component_property: delete one custom property.
The four built-in fields (Reference, Value, Footprint, Datasheet) are
protected and rejected.
edit_schematic_component enhancements:
- New `properties` parameter: map of property name to either a string
value or a full spec object { value, x?, y?, angle?, hide?, fontSize? }.
Adds the property when missing, otherwise updates the existing field
(and optionally its label position / visibility). Lets a single tool
call attach an entire BOM payload to a component.
- New `removeProperties` parameter: list of custom property names to
delete in the same call.
- Property values are now backslash-escaped so descriptions containing
a double-quote or a backslash no longer corrupt the .kicad_sch file.
- New properties default to (hide yes) so they appear in BOM exports
without cluttering the schematic canvas.
get_schematic_component description clarified to highlight that it
already returns every field on the symbol, including custom ones.
New MCP prompt component_sourcing_properties guides agents through the
conventional property names recognised by downstream BOM tooling and
the recommended call sequence.
Implementation (python/kicad_interface.py):
- _PROTECTED_PROPERTY_FIELDS frozenset
- _escape_sexpr_string / _find_matching_paren static helpers
- _set_property_in_block / _set_hide_on_property /
_remove_property_from_block surgical text-level edits that preserve
formatting and the property's UUID
- _handle_edit_schematic_component rewritten to orchestrate
add/update/remove and return a per-property summary
- New handlers _handle_set_schematic_component_property and
_handle_remove_schematic_component_property registered in the
command dispatch table
Tests (tests/test_schematic_component_properties.py):
32 tests covering escape helper, paren matcher, add/update/remove
(single + batched), full spec dicts, default position, default
(hide yes), special-character escaping, UUID preservation, protected
built-in field rejection, no-op removal, both new convenience tools,
and input validation. All 590 tests in the project still pass.
Docs: README, SCHEMATIC_TOOLS_REFERENCE, TOOL_INVENTORY, CHANGELOG.
Adds two new MCP tools for working with free-form text annotations
(SCH_TEXT elements) in KiCad schematics:
- add_schematic_text: place a text note with optional angle, font size,
bold/italic, and justification
- list_schematic_texts: list all text annotations with optional
case-insensitive substring filter
Includes WireManager.add_text / list_texts using _text_insert + sexpdata,
handler dispatch in KiCADInterface, TypeScript tool definitions, registry
entry, reference doc updates, and 30 unit tests.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
15 tests covering:
- Empty schematic → empty maps
- Global / local / hierarchical labels at pin endpoints
- Net propagation through one and two wire hops
- Unconnected pin stays absent from map
- Power (#PWR) and flag (#FLG) symbols excluded from component map
- Components in sub-sheets collected alongside top-level components
- 90° rotated symbol produces correct absolute pin positions
Uses MagicMock skip.Schematic objects patched in both the walker
import and commands.pin_locator module namespace; lib_symbols are
provided in real on-disk .kicad_sch files so sexpdata parsing runs
without mocking.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Covers create_component_instance and _handle_add_schematic_component:
- default unit=1 behaviour
- explicit unit 2 and 4 written to (unit N) in schematic S-expression
- (instances ...) block also records the correct unit
- multiple units of the same reference placed independently
- handler param validation (missing schematicPath, missing component)
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Covers the three bugs fixed in the previous commit:
- TestAddComponentNoTrailingUnderscore (integration): verifies clone() + no extra append()
- TestPinLocatorYAxisNegation (unit): rotation=0 and 90° cases with y-negation
- TestPinLocatorReferenceRstrip (unit): lookup tolerates 'R1_' artifact from kicad-skip
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Moves a net label (local, global, or hierarchical) to a new position in
place, avoiding the error-prone delete-then-re-add workflow. Supports an
optional currentPosition disambiguator and labelType filter.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Mechanical application of the `.gitattributes` rules from the prior commit.
All 50 files differ only in line endings — verified by
`git diff --cached --ignore-all-space` being empty.
Before: main had 42 CRLF + 27 LF Python files plus mixed-ending in YAML,
templates, and shell scripts. After: every text file is LF (except the
Windows-native *.ps1, *.bat scripts which remain CRLF per gitattributes).
This eliminates the noisy-diff failure mode seen in PR #102, where a
small logic change produced a 918-line diff due to whole-file CRLF→LF
conversion.
Add optional netName (exact case-sensitive match) and labelType
(net/global/power enum) parameters. Both are optional and AND
together when combined. Omitting both preserves current behaviour.
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
Parser used a 5000-char heuristic slice per symbol; any symbol block
shorter than 5000 chars bled into the next one, and last-write-wins in
the properties dict ensured the neighbor's data clobbered the target.
Reported as Simulation_SPICE:OPAMP returning PJFET data.
Switch to parenthesis-depth tracking to find the true end of each
(symbol ...) block. Also surface Sim.Pins so agents can read opamp pin
numbering without inferring it from schematic placement.
Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
Two new tools for managing hierarchical schematic connections:
- add_schematic_hierarchical_label: create sheet interface ports on
sub-sheet schematics. These are the sub-sheet side of hierarchical
connections, linking to sheet pins on the parent.
- add_sheet_pin: add pins to sheet symbol blocks on the parent
schematic. Targets the correct sheet by matching the Sheetname
property. The pinName must match a hierarchical_label in the
sub-sheet.
Both tools use text-based S-expression insertion (not sexpdata
round-trip) to preserve KiCad's native file formatting. Labels
include proper justification based on orientation: left-justify for
rightward labels (0°), right-justify for leftward labels (180°).
Wire manager additions:
- _find_insertion_point(): locates sheet_instances block or final paren
- _text_insert(): inserts formatted S-expression text at the right position
- _make_hierarchical_label_text(): generates hierarchical_label S-expression
- _make_sheet_pin_text(): generates sheet pin S-expression
- WireManager.add_hierarchical_label(): static method for label insertion
- WireManager.add_sheet_pin(): static method for pin insertion into
named sheet blocks
12 unit tests covering insertion, orientation/justification mapping,
parameter validation, multi-sheet targeting, and error handling.
get_net_connections() built its match-point set exclusively from wire
endpoints. If a net label was placed directly at a pin endpoint with no
wire segment (valid KiCad style), the function returned 0 connections
because connected_wire_points was empty.
Fix: build all_match_points as the union of connected wire endpoints and
label positions. Pin matching checks both, so label-at-pin schematics
produce correct netlists alongside traditional wired schematics.
Also handles the case where the schematic object has no wire attribute
at all — instead of returning early, we continue with label positions
as the sole match points.
Tests: tests/test_label_at_pin_net_connections.py (11 unit tests)
- label at pin, no wire → pin found
- label at pin, within/outside tolerance
- label via wire → still found (regression)
- mixed wired and direct labels on same net
- no wire attribute → still detects label-at-pin
- template symbols skipped
Black/isort/flake8/mypy verified manually (pre-commit local npm hook
fails to install on Windows due to MobaXterm path environment issue).
Two issues with run_erc on KiCad 9:
1. kicad-cli returns non-zero exit code when ERC violations exist.
The handler treated this as a command failure and returned early
with success=false, even though valid JSON output was produced.
Fix: check for output file existence instead of exit code.
2. KiCad 9 nests violations under sheets[].violations instead of
(or in addition to) the top-level violations[] array used by
KiCad 8. The handler only read the top-level array, reporting
0 violations on schematics with sub-sheets.
Fix: iterate sheets[] and collect all nested violations.
Both fixes are backward-compatible with KiCad 8.
6 unit tests added covering non-zero exit codes, KiCad 8 top-level
violations, KiCad 9 sheets[] nesting, mixed structures, zero
violations, and missing output files.
export_netlist was returning "Unknown command" because no Python handler
existed. generate_netlist was timing out (30s) due to an O(nets × components
× pins) wire-graph algorithm with a new PinLocator instantiated per net.
Both handlers now delegate to `kicad-cli sch export netlist`:
- export_netlist: new handler; writes KiCad XML / Spice / Cadstar / OrcadPCB2
to the caller-supplied outputPath. Added schematicPath parameter to the TS
tool definition (was absent, making file export impossible).
- generate_netlist: replaces the slow wire-graph with kicad-cli + XML parse;
returns the same {components, nets} JSON the TS handler already expected.
Also adds _find_kicad_cli_static() so both handlers share CLI discovery
without depending on ExportCommands (which requires a loaded pcbnew board).
Cleaned up generate_netlist schema in tool_schemas.py (removed outputPath and
format fields the handler never used), updated MCP tool descriptions and
SCHEMATIC_TOOLS_REFERENCE.md to clearly distinguish the two tools.
26 unit tests added covering parameter validation, subprocess mocking,
format mapping, XML→JSON parsing, and error/timeout propagation.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Half of all valid KiCAD schematic pin positions are on the 50-mil
(1.27mm) grid but not the 100-mil (2.54mm) grid — e.g. 26.67mm = 21 ×
1.27mm. Snapping to 2.54mm displaced those coordinates by 1.27mm,
moving labels off their pins and increasing floating-label count.
KiCAD source confirms: DEFAULT_CONNECTION_GRID_MILS = 50 and the ERC
off-grid check uses exact integer modulo against this value, so any
displacement breaks connectivity unconditionally.
Also update the kicad-source absolute path in CLAUDE.md.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
get_pin_net was a superset of get_wire_connections with the same
coordinate-based flood-fill but two extra response fields (net, query_point)
and a reference+pin input mode. Having both tools confused LLM tool selection.
get_wire_connections now:
- Returns net (label name or null) and query_point in all response paths
- Accepts reference+pin input in addition to x/y coordinates,
resolving the pin endpoint via PinLocator internally
get_pin_net tool, handler, schema, TS registration, and tests removed.
test_wire_connectivity.py updated with coverage for all new behaviour.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Answers "what net is pin X of component Y on?" without requiring
callers to triangulate from list_schematic_nets or know a wire
coordinate first.
Accepts either {reference, pin} (resolved via PinLocator) or {x, y}
coordinate. Returns net label name (or null for unnamed nets), all
connected pins, wire segments, and the resolved query point.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Adds a new MCP tool that snaps wire endpoints, junction positions, and
net label coordinates to the nearest grid point (default 2.54 mm). Off-grid
coordinates cause wires that appear visually connected to fail ERC checks
because KiCAD uses exact IU integer matching internally; this tool eliminates
that class of error before running ERC.
- python/commands/schematic_snap.py: core snap logic with in-place sexp mutation
- python/kicad_interface.py: route + handler
- python/schemas/tool_schemas.py: JSON schema (gridSize, elements params)
- src/tools/schematic.ts: TypeScript MCP tool registration
- tests/test_snap_to_grid.py: 20 unit + integration tests (all passing)
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Detects wire segments with at least one dangling endpoint — an endpoint
not connected to a component pin, net label, or another wire. These
cause ERC 'wire end unconnected' violations and are a common symptom of
incomplete routing or stray stub wires.
Algorithm uses exact KiCad IU (10 000 IU/mm) coordinate matching,
consistent with wire_connectivity.py:
1. Build an endpoint-frequency map for all wires (IU precision)
2. Collect anchored IU points: component pins (via PinLocator),
net labels / global_labels, power symbol pins
(via _parse_virtual_connections)
3. An endpoint is dangling when it is touched by exactly one wire AND
is not an anchored point; the containing wire is reported
Does not require the KiCad UI to be running.
Changes:
python/commands/schematic_analysis.py — find_orphaned_wires() function
python/kicad_interface.py — handler + route registration
python/schemas/tool_schemas.py — MCP schema entry
src/tools/schematic.ts — TypeScript server.tool() call
tests/test_schematic_analysis.py — 7 integration tests
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
add_schematic_net_label now accepts optional componentRef + pinNumber to
snap the label directly to the exact pin endpoint via PinLocator, removing
all approximation risk. The response always includes actual_position and,
when snapping was used, snapped_to_pin — so the caller gets confirmation
of exactly where the label landed.
connect_to_net return type changed from bool to Dict, returning
pin_location, label_location, and wire_stub on success so agents no
longer need a separate verification call to confirm placement.
connect_passthrough updated to check result.get("success") against the
new dict return. tool_schemas.py and schematic.ts updated to match
(position is now optional, componentRef/pinNumber/labelType/orientation
added, connect_to_net schema field names corrected).
17 new unit tests in tests/test_net_label_pin_snapping.py.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Move all Python test files from python/tests/ to the top-level tests/
directory to match the project's CONTRIBUTING.md guidelines. Update
sys.path inserts and template path references to reflect the new
location.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Previously passing mirror='x' or mirror='y' to rotate_schematic_component
always raised:
'NoneType' object has no attribute 'value'
Root cause: kicad-skip has no API for setting (mirror x/y) on a placed
symbol instance. The handler tried to use a non-existent kicad-skip
attribute, returning None, then calling .value on it.
Fix: add _apply_mirror_to_symbol_sexp() which directly patches the
(mirror x/y) S-expression token in the .kicad_sch file. The rotate
handler now applies rotation via kicad-skip (which works fine) and
delegates mirror to this helper.
The helper:
- Inserts (mirror x/y) immediately after the (at x y rot) token
- Removes any existing mirror token before inserting the new one
(prevents duplicate tokens when toggling axis)
- Returns False gracefully when the reference is not found
Tests: 6 unit tests in tests/test_rotate_schematic_mirror.py
covering: add x, add y, remove, replace, unknown ref, no-mirror smoke test.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Previously the path argument to create_schematic() was accepted by the
tool schema but silently ignored in SchematicManager.create_schematic()
(python/commands/schematic.py). The schematic file was always written
using only the bare filename, resolving to the MCP server's working
directory.
On systems where that directory is not writable (e.g. Program Files,
OneDrive-synced folders) this caused:
[Errno 13] Permission denied: 'myproject.kicad_sch'
Fix:
- Add path: Optional[str] = None parameter to SchematicManager.create_schematic()
- Compute output_path as os.path.join(path, base_name) when path is given
- Forward the resolved path from _handle_create_schematic() into create_schematic()
Tests: added tests/test_create_schematic_path.py with three unit tests
covering: path respected, no-path fallback, and no double-suffix on .kicad_sch names.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
The PR added a second server.tool("move_schematic_component", ...) at line 1127
without removing the original registration at line 722, causing the server to
fail on startup with "Tool move_schematic_component is already registered".
Also adds tests/test_ts_tool_registry.py which scans all src/tools/**/*.ts files
for duplicate server.tool() names so this class of bug is caught automatically.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Add isort configuration (profile=black, line_length=100) to pyproject.toml,
add isort pre-commit hook, and auto-sort imports across all Python source files.
Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
Add [tool.black] config to pyproject.toml and Black hook to
.pre-commit-config.yaml (rev 26.3.1), then auto-format all Python
source and test files with line-length=100, target-version=py310.
Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>