Commit Graph

48 Commits

Author SHA1 Message Date
Eugene Mikhantyev
84ba778d60 Merge pull request #145 from inktomi/fix/pin-world-y-flip
fix: apply Y-axis flip in WireDragger.pin_world_xy
2026-05-03 21:43:27 +01:00
Matthew Runo
09ec6aaeb5 fix: escape newlines in WireManager.add_text
The KiCad s-expression parser rejects raw newline and carriage-return
characters inside quoted string literals — a multi-line text annotation
written through `add_text` produced a `.kicad_sch` file that eeschema
silently tolerated but `kicad-cli sch ...` refused with "Failed to load
schematic." The escape pass only handled backslashes and double quotes.

Add `\\n` → `\\\\n` and `\\r` → `\\\\r` to the same escape chain. Order
matters: backslashes are escaped first so we don't double-escape our
own escapes.

A new regression test (`test_escapes_newlines_in_multiline_text`)
checks both that the resulting quoted string literal contains no raw
newline characters and that the file round-trips cleanly through the
sexpdata parser.

End-to-end smoke: a 4-line annotation written through the patched
add_text now passes `kicad-cli sch erc` (exit 0) where the previous
behaviour failed parse.

Note: the same escape gap exists in `_make_hierarchical_label_text`
and `_make_sheet_pin_text` for unescaped quotes/newlines in the user-
supplied text. Not fixed here to keep this PR scoped to the documented
add_text bug; happy to fold it in if a reviewer prefers.
2026-05-01 10:03:49 -07:00
Matthew Runo
bf74b85caf fix: apply Y-axis flip in WireDragger.pin_world_xy
Library symbol pins are stored Y-up (positive Y is upward in the symbol
editor's coordinate system) but `.kicad_sch` is Y-down (positive Y is
downward in the schematic). `pin_world_xy` was returning `sym_y + ry`
without negating the rotated lib Y, so for any non-symmetric symbol
pin 1 and pin 2 ended up at swapped world positions.

For symmetric two-pin passives (R, C non-polarized) this was invisible
because pin 1 and pin 2 are electrically equivalent. For polarized
parts — electrolytic and polymer caps, diodes, MOSFETs, BJTs — it
silently swapped polarity. A label snapped to a polarized cap's pin 1
ended up on pin 2, which is catastrophic at first power-up.

The order matches eeschema's actual transformation:
  mirror in lib space → Y-flip to screen → rotate → translate.

The existing regression test in test_pin_locator_y_flip.py was already
written with the correct expected coordinates but the matching code fix
was never landed; that test now passes.

Three tests in test_move_with_wire_preservation.py had baked the buggy
expected coordinates into their assertions; updated those to the correct
y-flipped values. The touching-pin fixture had to flip R2's Y from
-7.62 to +7.62 so the two pins still meet under the corrected formula.

Verified end-to-end on a 46-component aerospace PDB schematic: all
8 polarized-part pins (4 polymer caps + 4 TVS diodes) now produce
world coordinates that match the labels actually placed in the file.
2026-05-01 10:02:13 -07:00
Eugene Mikhantyev
5907954b3e Fix two regressions from PR #88 (rotate/mirror)
1. add_schematic_net_label failed on schematics with no existing labels.
   The clone-based path required a pre-existing label to copy from;
   the documented "fallback to sexpdata" was a misleading log line —
   the RuntimeError was caught and the call silently returned False.
   Restore hand-built sexpdata construction (without the buggy
   fields_autoplaced token, with orientation-aware justify).

2. get_pin_angle returned the wrong angle for every mirrored symbol
   (off by exactly 180°, all rotations, both mirror axes). The
   mirror_x and mirror_y formulas were swapped relative to the
   pin_world_xy convention — pin_world_xy mirrors a position by
   flipping its local axis component, so the matching angle
   transform is (180 - θ) for mirror_x and -θ for mirror_y.

Add regression tests:
- test_add_label_empty_schematic.py — first label on empty schematic,
  orientation-aware justify.
- test_get_pin_angle.py — full 24-case matrix
  (4 rotations × 3 mirror states × 2 pins).
2026-04-29 21:40:39 +01:00
Michael Parment
a6b4f92e4b fix: stub annotations module and add python/ to sys.path in smoke test
Upstream added `from annotations import AnnotationLoader` and moved
`from commands.wire_manager import WireManager` to module-level in
kicad_interface.py. The smoke test now stubs annotations and ensures
python/ is on sys.path so commands.* imports resolve without installing.
2026-04-28 13:38:12 +02:00
Michael Parment
53e656b952 fix: rotate_schematic_component uses sexpdata API and drags wires
Previously the handler used kicad-skip to apply rotation and mirror.
kicad-skip has no API for (mirror x/y) on placed symbols, causing:
  'NoneType' object has no attribute 'value'

Fix:
- Rewrote _handle_rotate_schematic_component to use sexpdata (same
  approach as move_schematic_component) for both rotation and mirror
- Added WireDragger.compute_pin_positions_for_rotation: computes old
  and new pin world positions when rotation/mirror changes at fixed (x,y)
- Added WireDragger.update_symbol_rotation_mirror: updates (at) rotation
  and adds/removes/replaces the (mirror x/y) sexpdata token cleanly
- Connected wires now follow pin positions after rotate/mirror via the
  existing WireDragger.drag_wires infrastructure

Tests: 10 unit tests in tests/test_rotate_schematic_mirror.py covering
update_symbol_rotation_mirror, compute_pin_positions_for_rotation, and
a handler smoke test.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-28 13:32:43 +02:00
Eugene Mikhantyev
7a6558b9fa Auto-sync junctions on wire/symbol mutations
Replaces the manual add_schematic_junction tool with automatic junction
management. WireManager.sync_junctions inserts/removes junction dots
based on wire endpoints plus component pin positions and is invoked
after add_wire, add_polyline_wire, delete_wire, move, and rotate.

- Pin-aware: parses lib_symbols and applies KiCad's mirror/rotate/
  translate transform to compute world pin coordinates
- Multi-unit safe: filters lib_symbols sub-units by the placed
  symbol's (unit N) field plus the unit-0 common body
- Removes the now-unused WireManager.add_junction static method
- Updates CHANGELOG [Unreleased] with the tool removal notice
- Adds .mcp.json to .gitignore (machine-local paths)

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-04-26 14:59:47 +01:00
Eugene Mikhantyev
0efcd923c1 Merge pull request #133 from johndev7000/fix/pin-locator-y-double-negation
fix: remove duplicate Y-axis negation in PinLocator.get_pin_location
2026-04-25 23:29:43 +01:00
John Dev
1c25c85de0 fix: remove duplicate Y-axis negation in PinLocator.get_pin_location
The symbol-to-schematic y-flip was applied twice in sequence (two identical
negation blocks with matching comments), cancelling out and leaving pin
Y-coordinates mirrored about the placement Y. For symmetric passives the
bug is invisible (pin 1 and pin 2 are electrically interchangeable); for
ICs with non-equivalent pins (power pins, opamp inputs, etc.) this causes
tools that go through PinLocator — connect_to_net, add_schematic_connection,
add_schematic_net_label with componentRef+pinNumber — to place connections
at the mirror-flipped pin. Verified against kicad-cli generate_netlist
ground truth: on a Device:R placed at (111.76, 83.82), pin 1 resolves to
y=80.01 (actual) vs y=87.63 (pre-fix).

This is a regression of PR #103, which originally fixed the y-negation;
the redundant second block was added subsequently.

Includes a regression test with both a straight Device:R and a rotated
Device:C to exercise the y-flip + rotation pipeline.
2026-04-23 19:19:14 +01:00
William Viana
e96637c6c3 fix: locate placed symbols when (lib_name) precedes (lib_id)
KiCad serialises rescued or locally-customised library entries with an
extra (lib_name "...") child before (lib_id "..."):

    (symbol
      (lib_name "RESISTOR_0603_4")
      (lib_id "MF_Passives:RESISTOR_0603")
      (at 132.08 44.45 90)
      ...)

The block-matching regex in _handle_get_schematic_component,
_handle_edit_schematic_component, and _handle_delete_schematic_component
required (lib_id IMMEDIATELY after (symbol, so any placed component
using this form was silently invisible to lookup. The user-visible
symptom is "Component '<ref>' not found in schematic" even though the
component is plainly present (and reachable through list / IPC paths).
This bug also affected set/remove_schematic_component_property and the
existing footprint/value/reference rewriting paths in edit, since they
all share the same lookup code.

The parent-position lookup used a similarly-strict regex
((symbol (lib_id "...") (at ...))), which silently fell back to (0,0)
on (lib_name)-first symbols and caused new properties added through
the custom-properties path to anchor at the schematic origin instead
of the parent symbol.

Fix: relax the symbol-block opening pattern to (symbol\s+\( — matching
any opening paren after (symbol — and read the symbol's origin from
the first (at ...) inside the block. Library-definition entries inside
(lib_symbols ...) are still excluded by the existing range check
(they use the (symbol "name" ...) form with a quoted string, not a
paren).

Adds 7 regression tests in TestLibNameBeforeLibIdOrdering using a
real-world (lib_name)-first resistor block, covering get / edit /
set-property / remove-property / delete and verifying that newly
added properties anchor to the symbol origin instead of (0, 0).
2026-04-21 10:12:52 -07:00
mixelpixx
28d9f3353e Merge pull request #115 from thesamprice/test/add-schematic-component-unit
test: add unit parameter tests for add_schematic_component
2026-04-21 09:15:59 -04:00
mixelpixx
4d8dcf7dbb Merge pull request #103 from tecnovel/main
fix: correct pin location, symbol reference dedup, and ERC violation parsing
2026-04-21 09:00:09 -04:00
mixelpixx
74b4e717f8 Merge pull request #120 from thesamprice/feat/hierarchical-sync
feat: walk all sub-sheets to build hierarchical pad→net map for sync_schematic_to_board
2026-04-21 08:59:39 -04:00
William Viana
4d7843c03a feat: support arbitrary custom properties on schematic components
Promotes BOM / sourcing fields (MPN, Manufacturer, DigiKey_PN, LCSC,
JLCPCB_PN, Voltage, Tolerance, Dielectric, ...) to first-class citizens
on placed schematic symbols.

New MCP tools:
- set_schematic_component_property: add or update one custom property
  on a component (convenience wrapper around edit_schematic_component).
- remove_schematic_component_property: delete one custom property.
  The four built-in fields (Reference, Value, Footprint, Datasheet) are
  protected and rejected.

edit_schematic_component enhancements:
- New `properties` parameter: map of property name to either a string
  value or a full spec object { value, x?, y?, angle?, hide?, fontSize? }.
  Adds the property when missing, otherwise updates the existing field
  (and optionally its label position / visibility). Lets a single tool
  call attach an entire BOM payload to a component.
- New `removeProperties` parameter: list of custom property names to
  delete in the same call.
- Property values are now backslash-escaped so descriptions containing
  a double-quote or a backslash no longer corrupt the .kicad_sch file.
- New properties default to (hide yes) so they appear in BOM exports
  without cluttering the schematic canvas.

get_schematic_component description clarified to highlight that it
already returns every field on the symbol, including custom ones.

New MCP prompt component_sourcing_properties guides agents through the
conventional property names recognised by downstream BOM tooling and
the recommended call sequence.

Implementation (python/kicad_interface.py):
- _PROTECTED_PROPERTY_FIELDS frozenset
- _escape_sexpr_string / _find_matching_paren static helpers
- _set_property_in_block / _set_hide_on_property /
  _remove_property_from_block surgical text-level edits that preserve
  formatting and the property's UUID
- _handle_edit_schematic_component rewritten to orchestrate
  add/update/remove and return a per-property summary
- New handlers _handle_set_schematic_component_property and
  _handle_remove_schematic_component_property registered in the
  command dispatch table

Tests (tests/test_schematic_component_properties.py):
32 tests covering escape helper, paren matcher, add/update/remove
(single + batched), full spec dicts, default position, default
(hide yes), special-character escaping, UUID preservation, protected
built-in field rejection, no-op removal, both new convenience tools,
and input validation. All 590 tests in the project still pass.

Docs: README, SCHEMATIC_TOOLS_REFERENCE, TOOL_INVENTORY, CHANGELOG.
2026-04-20 17:36:38 -07:00
Eugene Mikhantyev
e5916005a0 feat: add add_schematic_text and list_schematic_texts tools
Adds two new MCP tools for working with free-form text annotations
(SCH_TEXT elements) in KiCad schematics:

- add_schematic_text: place a text note with optional angle, font size,
  bold/italic, and justification
- list_schematic_texts: list all text annotations with optional
  case-insensitive substring filter

Includes WireManager.add_text / list_texts using _text_insert + sexpdata,
handler dispatch in KiCADInterface, TypeScript tool definitions, registry
entry, reference doc updates, and 30 unit tests.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-19 21:26:39 +01:00
Samuel Price
8a4281211e test: add unit tests for _build_hierarchical_pad_net_map
15 tests covering:
- Empty schematic → empty maps
- Global / local / hierarchical labels at pin endpoints
- Net propagation through one and two wire hops
- Unconnected pin stays absent from map
- Power (#PWR) and flag (#FLG) symbols excluded from component map
- Components in sub-sheets collected alongside top-level components
- 90° rotated symbol produces correct absolute pin positions

Uses MagicMock skip.Schematic objects patched in both the walker
import and commands.pin_locator module namespace; lib_symbols are
provided in real on-disk .kicad_sch files so sexpdata parsing runs
without mocking.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-19 12:52:02 -04:00
Samuel Price
b3940b9331 test: add unit parameter tests for add_schematic_component
Covers create_component_instance and _handle_add_schematic_component:
- default unit=1 behaviour
- explicit unit 2 and 4 written to (unit N) in schematic S-expression
- (instances ...) block also records the correct unit
- multiple units of the same reference placed independently
- handler param validation (missing schematicPath, missing component)

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-19 10:15:02 -04:00
Eugene Mikhantyev
e164f12ffa tests: add regression tests for pin location y-axis, reference trailing underscore, and clone dedup
Covers the three bugs fixed in the previous commit:
- TestAddComponentNoTrailingUnderscore (integration): verifies clone() + no extra append()
- TestPinLocatorYAxisNegation (unit): rotation=0 and 90° cases with y-negation
- TestPinLocatorReferenceRstrip (unit): lookup tolerates 'R1_' artifact from kicad-skip

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-18 23:42:08 +01:00
Eugene Mikhantyev
c8f6a58116 feat: add move_schematic_net_label tool
Moves a net label (local, global, or hierarchical) to a new position in
place, avoiding the error-prone delete-then-re-add workflow. Supports an
optional currentPosition disambiguator and labelType filter.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-18 23:14:29 +01:00
Eugene Mikhantyev
bfc25639c2 chore: normalize all tracked files to LF line endings
Mechanical application of the `.gitattributes` rules from the prior commit.
All 50 files differ only in line endings — verified by
`git diff --cached --ignore-all-space` being empty.

Before: main had 42 CRLF + 27 LF Python files plus mixed-ending in YAML,
templates, and shell scripts. After: every text file is LF (except the
Windows-native *.ps1, *.bat scripts which remain CRLF per gitattributes).

This eliminates the noisy-diff failure mode seen in PR #102, where a
small logic change produced a 918-line diff due to whole-file CRLF→LF
conversion.
2026-04-18 15:23:00 +01:00
Eugene Mikhantyev
9a66f5e0b9 feat: add netName and labelType filters to list_schematic_labels
Add optional netName (exact case-sensitive match) and labelType
(net/global/power enum) parameters. Both are optional and AND
together when combined. Omitting both preserves current behaviour.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-04-18 15:07:23 +01:00
Eugene Mikhantyev
4ec63f7544 Merge pull request #107 from mixelpixx/fix/get-symbol-info-spice-opamp
fix: get_symbol_info returns neighboring symbol's data for short blocks
2026-04-18 14:46:49 +01:00
Eugene Mikhantyev
e5cd924b0a Merge pull request #102 from ffindog/fix/netlist-label-at-pin
fix: resolve nets when labels are placed directly at pin endpoints
2026-04-18 14:37:46 +01:00
Tom
a422e4eb0c Merge pull request #87 from tnemrap/fix/create-schematic-path
fix: create_schematic now respects the path parameter
2026-04-18 14:33:58 +02:00
Eugene Mikhantyev
55ec4950d9 fix: get_symbol_info returns wrong data for every small symbol
Parser used a 5000-char heuristic slice per symbol; any symbol block
shorter than 5000 chars bled into the next one, and last-write-wins in
the properties dict ensured the neighbor's data clobbered the target.
Reported as Simulation_SPICE:OPAMP returning PJFET data.

Switch to parenthesis-depth tracking to find the true end of each
(symbol ...) block. Also surface Sim.Pins so agents can read opamp pin
numbering without inferring it from schematic placement.

Co-Authored-By: Claude Opus 4.7 <noreply@anthropic.com>
2026-04-18 12:55:41 +01:00
Eugene Mikhantyev
e687fa39e1 Merge pull request #104 from LeahArmstrong/feat/hierarchy-tools
feat: add hierarchical label and sheet pin tools
2026-04-18 12:00:22 +01:00
Leah Armstrong
101b4e1dad feat: add hierarchy tools (hierarchical label + sheet pin)
Two new tools for managing hierarchical schematic connections:

- add_schematic_hierarchical_label: create sheet interface ports on
  sub-sheet schematics. These are the sub-sheet side of hierarchical
  connections, linking to sheet pins on the parent.

- add_sheet_pin: add pins to sheet symbol blocks on the parent
  schematic. Targets the correct sheet by matching the Sheetname
  property. The pinName must match a hierarchical_label in the
  sub-sheet.

Both tools use text-based S-expression insertion (not sexpdata
round-trip) to preserve KiCad's native file formatting. Labels
include proper justification based on orientation: left-justify for
rightward labels (0°), right-justify for leftward labels (180°).

Wire manager additions:
- _find_insertion_point(): locates sheet_instances block or final paren
- _text_insert(): inserts formatted S-expression text at the right position
- _make_hierarchical_label_text(): generates hierarchical_label S-expression
- _make_sheet_pin_text(): generates sheet pin S-expression
- WireManager.add_hierarchical_label(): static method for label insertion
- WireManager.add_sheet_pin(): static method for pin insertion into
  named sheet blocks

12 unit tests covering insertion, orientation/justification mapping,
parameter validation, multi-sheet targeting, and error handling.
2026-04-15 12:32:09 -04:00
ffindog
ef660afdb4 fix: resolve nets when labels are placed directly at pin endpoints
get_net_connections() built its match-point set exclusively from wire
endpoints. If a net label was placed directly at a pin endpoint with no
wire segment (valid KiCad style), the function returned 0 connections
because connected_wire_points was empty.

Fix: build all_match_points as the union of connected wire endpoints and
label positions. Pin matching checks both, so label-at-pin schematics
produce correct netlists alongside traditional wired schematics.

Also handles the case where the schematic object has no wire attribute
at all — instead of returning early, we continue with label positions
as the sole match points.

Tests: tests/test_label_at_pin_net_connections.py (11 unit tests)
  - label at pin, no wire → pin found
  - label at pin, within/outside tolerance
  - label via wire → still found (regression)
  - mixed wired and direct labels on same net
  - no wire attribute → still detects label-at-pin
  - template symbols skipped

Black/isort/flake8/mypy verified manually (pre-commit local npm hook
fails to install on Windows due to MobaXterm path environment issue).
2026-04-15 22:40:14 +10:00
Leah Armstrong
15d06e449a fix: ERC handler fails on KiCad 9 schematics
Two issues with run_erc on KiCad 9:

1. kicad-cli returns non-zero exit code when ERC violations exist.
   The handler treated this as a command failure and returned early
   with success=false, even though valid JSON output was produced.
   Fix: check for output file existence instead of exit code.

2. KiCad 9 nests violations under sheets[].violations instead of
   (or in addition to) the top-level violations[] array used by
   KiCad 8. The handler only read the top-level array, reporting
   0 violations on schematics with sub-sheets.
   Fix: iterate sheets[] and collect all nested violations.

Both fixes are backward-compatible with KiCad 8.

6 unit tests added covering non-zero exit codes, KiCad 8 top-level
violations, KiCad 9 sheets[] nesting, mixed structures, zero
violations, and missing output files.
2026-04-14 12:52:17 -04:00
Eugene Mikhantyev
c7b0e3105b fix: implement export_netlist handler and rewrite generate_netlist to use kicad-cli
export_netlist was returning "Unknown command" because no Python handler
existed. generate_netlist was timing out (30s) due to an O(nets × components
× pins) wire-graph algorithm with a new PinLocator instantiated per net.

Both handlers now delegate to `kicad-cli sch export netlist`:
- export_netlist: new handler; writes KiCad XML / Spice / Cadstar / OrcadPCB2
  to the caller-supplied outputPath. Added schematicPath parameter to the TS
  tool definition (was absent, making file export impossible).
- generate_netlist: replaces the slow wire-graph with kicad-cli + XML parse;
  returns the same {components, nets} JSON the TS handler already expected.

Also adds _find_kicad_cli_static() so both handlers share CLI discovery
without depending on ExportCommands (which requires a loaded pcbnew board).

Cleaned up generate_netlist schema in tool_schemas.py (removed outputPath and
format fields the handler never used), updated MCP tool descriptions and
SCHEMATIC_TOOLS_REFERENCE.md to clearly distinguish the two tools.

26 unit tests added covering parameter validation, subprocess mocking,
format mapping, XML→JSON parsing, and error/timeout propagation.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-12 18:52:46 +01:00
Eugene Mikhantyev
ba09fc4e0f fix: change snap_to_grid default grid from 2.54mm to 1.27mm (50 mil)
Half of all valid KiCAD schematic pin positions are on the 50-mil
(1.27mm) grid but not the 100-mil (2.54mm) grid — e.g. 26.67mm = 21 ×
1.27mm. Snapping to 2.54mm displaced those coordinates by 1.27mm,
moving labels off their pins and increasing floating-label count.

KiCAD source confirms: DEFAULT_CONNECTION_GRID_MILS = 50 and the ERC
off-grid check uses exact integer modulo against this value, so any
displacement breaks connectivity unconditionally.

Also update the kicad-source absolute path in CLAUDE.md.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-12 18:10:55 +01:00
Eugene Mikhantyev
4f733bb3db refactor: consolidate get_pin_net into get_wire_connections
get_pin_net was a superset of get_wire_connections with the same
coordinate-based flood-fill but two extra response fields (net, query_point)
and a reference+pin input mode. Having both tools confused LLM tool selection.

get_wire_connections now:
- Returns net (label name or null) and query_point in all response paths
- Accepts reference+pin input in addition to x/y coordinates,
  resolving the pin endpoint via PinLocator internally

get_pin_net tool, handler, schema, TS registration, and tests removed.
test_wire_connectivity.py updated with coverage for all new behaviour.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-12 17:02:35 +01:00
Eugene Mikhantyev
f73d8d9795 feat: warn on case-mismatched net label names in add_schematic_net_label
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-12 15:49:15 +01:00
Eugene Mikhantyev
4895bf169c feat: add connected_pin_count to list_schematic_nets and list_floating_labels tool
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-12 15:46:32 +01:00
Eugene Mikhantyev
e826cf3d32 feat: add get_net_at_point tool for coordinate-based net lookup
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-12 15:29:46 +01:00
Eugene Mikhantyev
5f3c20d308 feat: add get_pin_net tool for direct net/pin queries
Answers "what net is pin X of component Y on?" without requiring
callers to triangulate from list_schematic_nets or know a wire
coordinate first.

Accepts either {reference, pin} (resolved via PinLocator) or {x, y}
coordinate. Returns net label name (or null for unnamed nets), all
connected pins, wire segments, and the resolved query point.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-12 15:19:14 +01:00
Eugene Mikhantyev
9387683368 feat: add snap_to_grid schematic tool
Adds a new MCP tool that snaps wire endpoints, junction positions, and
net label coordinates to the nearest grid point (default 2.54 mm). Off-grid
coordinates cause wires that appear visually connected to fail ERC checks
because KiCAD uses exact IU integer matching internally; this tool eliminates
that class of error before running ERC.

- python/commands/schematic_snap.py: core snap logic with in-place sexp mutation
- python/kicad_interface.py: route + handler
- python/schemas/tool_schemas.py: JSON schema (gridSize, elements params)
- src/tools/schematic.ts: TypeScript MCP tool registration
- tests/test_snap_to_grid.py: 20 unit + integration tests (all passing)

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-12 15:03:35 +01:00
Eugene Mikhantyev
58bb08a252 feat: add find_orphaned_wires schematic analysis tool
Detects wire segments with at least one dangling endpoint — an endpoint
not connected to a component pin, net label, or another wire.  These
cause ERC 'wire end unconnected' violations and are a common symptom of
incomplete routing or stray stub wires.

Algorithm uses exact KiCad IU (10 000 IU/mm) coordinate matching,
consistent with wire_connectivity.py:
  1. Build an endpoint-frequency map for all wires (IU precision)
  2. Collect anchored IU points: component pins (via PinLocator),
     net labels / global_labels, power symbol pins
     (via _parse_virtual_connections)
  3. An endpoint is dangling when it is touched by exactly one wire AND
     is not an anchored point; the containing wire is reported

Does not require the KiCad UI to be running.

Changes:
  python/commands/schematic_analysis.py — find_orphaned_wires() function
  python/kicad_interface.py             — handler + route registration
  python/schemas/tool_schemas.py        — MCP schema entry
  src/tools/schematic.ts                — TypeScript server.tool() call
  tests/test_schematic_analysis.py      — 7 integration tests

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-12 14:44:12 +01:00
Eugene Mikhantyev
94125eda7f fix: add pin-snapping and coordinate feedback to net label tools
add_schematic_net_label now accepts optional componentRef + pinNumber to
snap the label directly to the exact pin endpoint via PinLocator, removing
all approximation risk.  The response always includes actual_position and,
when snapping was used, snapped_to_pin — so the caller gets confirmation
of exactly where the label landed.

connect_to_net return type changed from bool to Dict, returning
pin_location, label_location, and wire_stub on success so agents no
longer need a separate verification call to confirm placement.

connect_passthrough updated to check result.get("success") against the
new dict return.  tool_schemas.py and schematic.ts updated to match
(position is now optional, componentRef/pinNumber/labelType/orientation
added, connect_to_net schema field names corrected).

17 new unit tests in tests/test_net_label_pin_snapping.py.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-12 14:12:11 +01:00
Eugene Mikhantyev
5de932e2b3 refactor: consolidate python/tests/ into tests/ directory
Move all Python test files from python/tests/ to the top-level tests/
directory to match the project's CONTRIBUTING.md guidelines. Update
sys.path inserts and template path references to reflect the new
location.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-12 11:22:39 +01:00
Michael Parment
dd19828cba Revert "fix: rotate_schematic_component mirror parameter no longer crashes"
This reverts commit 6e80ccd013.
2026-04-09 09:25:17 +02:00
Michael Parment
6e80ccd013 fix: rotate_schematic_component mirror parameter no longer crashes
Previously passing mirror='x' or mirror='y' to rotate_schematic_component
always raised:
  'NoneType' object has no attribute 'value'

Root cause: kicad-skip has no API for setting (mirror x/y) on a placed
symbol instance. The handler tried to use a non-existent kicad-skip
attribute, returning None, then calling .value on it.

Fix: add _apply_mirror_to_symbol_sexp() which directly patches the
(mirror x/y) S-expression token in the .kicad_sch file. The rotate
handler now applies rotation via kicad-skip (which works fine) and
delegates mirror to this helper.

The helper:
- Inserts (mirror x/y) immediately after the (at x y rot) token
- Removes any existing mirror token before inserting the new one
  (prevents duplicate tokens when toggling axis)
- Returns False gracefully when the reference is not found

Tests: 6 unit tests in tests/test_rotate_schematic_mirror.py
covering: add x, add y, remove, replace, unknown ref, no-mirror smoke test.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-09 09:23:02 +02:00
Michael Parment
b3ca93a98d fix: create_schematic now respects the path parameter
Previously the path argument to create_schematic() was accepted by the
tool schema but silently ignored in SchematicManager.create_schematic()
(python/commands/schematic.py). The schematic file was always written
using only the bare filename, resolving to the MCP server's working
directory.

On systems where that directory is not writable (e.g. Program Files,
OneDrive-synced folders) this caused:
  [Errno 13] Permission denied: 'myproject.kicad_sch'

Fix:
- Add path: Optional[str] = None parameter to SchematicManager.create_schematic()
- Compute output_path as os.path.join(path, base_name) when path is given
- Forward the resolved path from _handle_create_schematic() into create_schematic()

Tests: added tests/test_create_schematic_path.py with three unit tests
covering: path respected, no-path fallback, and no double-suffix on .kicad_sch names.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-08 10:27:53 +02:00
Eugene Mikhantyev
c4f013e6c7 fix: remove duplicate move_schematic_component tool registration and add regression test
The PR added a second server.tool("move_schematic_component", ...) at line 1127
without removing the original registration at line 722, causing the server to
fail on startup with "Tool move_schematic_component is already registered".

Also adds tests/test_ts_tool_registry.py which scans all src/tools/**/*.ts files
for duplicate server.tool() names so this class of bug is caught automatically.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-29 23:45:21 +01:00
Eugene Mikhantyev
c44bd9205d style: sort Python imports with isort
Add isort configuration (profile=black, line_length=100) to pyproject.toml,
add isort pre-commit hook, and auto-sort imports across all Python source files.

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
2026-03-29 13:02:24 +01:00
Eugene Mikhantyev
75cead0860 style: apply Black formatting to all Python files
Add [tool.black] config to pyproject.toml and Black hook to
.pre-commit-config.yaml (rev 26.3.1), then auto-format all Python
source and test files with line-length=100, target-version=py310.

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
2026-03-29 13:01:08 +01:00
shuofengzhang
5678a5ee6c Handle relative XDG paths in platform helper 2026-03-10 04:02:38 +08:00
KiCAD MCP Bot
e4c7119c51 feat: Week 1 complete - Linux support + IPC API prep
🎉 Major v2.0 rebuild kickoff - Week 1 accomplished!

## Highlights

### Cross-Platform Support 🌍
-  Linux primary platform (Ubuntu/Debian tested)
-  Windows fully supported
-  macOS experimental support
-  Platform-agnostic path handling (XDG spec)
-  Auto-detection of KiCAD installation

### Infrastructure 🏗️
-  GitHub Actions CI/CD pipeline
-  Pytest framework with 20+ tests
-  Pre-commit hooks (Black, MyPy, ESLint)
-  Automated Linux installation script
-  Enhanced npm scripts

### IPC API Migration Prep 🚀
-  Comprehensive migration plan (30 pages)
-  Backend abstraction layer (800+ lines)
-  Factory pattern with auto-detection
-  SWIG backward compatibility wrapper
-  IPC backend skeleton ready

### Documentation 📚
-  Updated README (Linux installation)
-  CONTRIBUTING.md guide
-  Linux compatibility audit
-  IPC API migration plan
-  Session summaries
-  Platform-specific config templates

## Files Changed

- 27 files created
- ~3,000 lines of code/docs
- 8 comprehensive documentation pages
- 20+ unit tests
- 5 abstraction layer modules

## Next Steps

- Week 2: IPC API migration (project.py → component.py → routing.py)
- Migrate from deprecated SWIG to official IPC API
- JLCPCB/Digikey integration prep

🤖 Generated with Claude Code
https://claude.com/claude-code

Co-Authored-By: Claude <noreply@anthropic.com>
2025-10-25 20:48:00 -04:00