Commit Graph

18 Commits

Author SHA1 Message Date
Eugene Mikhantyev
5907954b3e Fix two regressions from PR #88 (rotate/mirror)
1. add_schematic_net_label failed on schematics with no existing labels.
   The clone-based path required a pre-existing label to copy from;
   the documented "fallback to sexpdata" was a misleading log line —
   the RuntimeError was caught and the call silently returned False.
   Restore hand-built sexpdata construction (without the buggy
   fields_autoplaced token, with orientation-aware justify).

2. get_pin_angle returned the wrong angle for every mirrored symbol
   (off by exactly 180°, all rotations, both mirror axes). The
   mirror_x and mirror_y formulas were swapped relative to the
   pin_world_xy convention — pin_world_xy mirrors a position by
   flipping its local axis component, so the matching angle
   transform is (180 - θ) for mirror_x and -θ for mirror_y.

Add regression tests:
- test_add_label_empty_schematic.py — first label on empty schematic,
  orientation-aware justify.
- test_get_pin_angle.py — full 24-case matrix
  (4 rotations × 3 mirror states × 2 pins).
2026-04-29 21:40:39 +01:00
Michael Parment
7cafbda127 fix: get_schematic_pin_locations now accounts for mirror flags
Previously get_pin_location and get_pin_angle read symbol state from a
kicad-skip cache that does not reflect (mirror x/y) tokens written by
rotate_schematic_component. Pin coordinates were always computed as if
the symbol was unmirrored.

Fix:
- Added _get_symbol_transform() which reads position, rotation, mirror_x,
  mirror_y, and lib_id directly from the .kicad_sch file via sexpdata +
  WireDragger.find_symbol (the authoritative source after a rotate/mirror)
- get_pin_location now delegates the full transform (mirror → rotate →
  translate) to WireDragger.pin_world_xy, matching the logic used by
  move_schematic_component and rotate_schematic_component
- get_pin_angle now applies mirror-induced angle reflection before adding
  symbol rotation: mirror_x negates the angle, mirror_y reflects across 180°

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-28 13:36:29 +02:00
John Dev
1c25c85de0 fix: remove duplicate Y-axis negation in PinLocator.get_pin_location
The symbol-to-schematic y-flip was applied twice in sequence (two identical
negation blocks with matching comments), cancelling out and leaving pin
Y-coordinates mirrored about the placement Y. For symmetric passives the
bug is invisible (pin 1 and pin 2 are electrically interchangeable); for
ICs with non-equivalent pins (power pins, opamp inputs, etc.) this causes
tools that go through PinLocator — connect_to_net, add_schematic_connection,
add_schematic_net_label with componentRef+pinNumber — to place connections
at the mirror-flipped pin. Verified against kicad-cli generate_netlist
ground truth: on a Device:R placed at (111.76, 83.82), pin 1 resolves to
y=80.01 (actual) vs y=87.63 (pre-fix).

This is a regression of PR #103, which originally fixed the y-negation;
the redundant second block was added subsequently.

Includes a regression test with both a straight Device:R and a rotated
Device:C to exercise the y-flip + rotation pipeline.
2026-04-23 19:19:14 +01:00
mixelpixx
4d8dcf7dbb Merge pull request #103 from tecnovel/main
fix: correct pin location, symbol reference dedup, and ERC violation parsing
2026-04-21 09:00:09 -04:00
William Viana
046f33d876 feat: multi-sheet net connectivity + sexp-based parsing reliability
Adds robust multi-sheet (hierarchical) net connectivity for KiCad
schematics and switches the wire/label parsing to a direct sexpdata
pipeline that bypasses kicad-skip's collection iteration, which was
silently dropping wires, labels, and symbol instances on real-world
schematics.

python/commands/wire_connectivity.py
  - New sexpdata helpers: _load_sexp, _parse_wires_sexp,
    _parse_labels_sexp, _parse_symbol_instances_sexp,
    _parse_hierarchical_labels_sexp, _discover_sub_sheets.
  - _build_adjacency now detects T-junctions (endpoint landing on
    another wire's interior segment) so adjacency captures connections
    KiCad doesn't represent as separate wire segments.
  - _find_connected_wires gains an interior-segment fallback so labels
    placed mid-wire still seed BFS correctly.
  - _parse_virtual_connections gathers label / global_label /
    hierarchical_label and power-symbol pin positions, with a
    kicad-skip fallback for unit tests that mock the schematic.
  - _find_pins_on_net rebuilds pin positions from sexpdata symbol
    instances (with mirror_x/mirror_y/rotation handling) and uses a
    plus/minus 1 IU tolerance for floating-point edge cases.
  - get_connections_for_net walks the top sheet plus every recursively
    discovered sub-sheet, deduping pins across sheets.

python/commands/pin_locator.py
  - lib_id matching now falls back to a bare-name + unit-suffix match
    so instances like "stat-tis-custom:BAT_18650" resolve to
    lib_symbols entries like "BAT_18650_3".
  - Pin position math now y-negates lib_symbols coords, applies
    mirror_x/mirror_y in local coords before rotation, and propagates
    the same transform into get_pin_orientation so downstream callers
    get a correct outward angle for mirrored symbols.

python/commands/connection_schematic.py
  - generate_netlist now collects nets from both label and
    global_label and routes them through get_connections_for_net so
    netlists reflect cross-sheet connectivity instead of single-sheet
    label-only nets.

python/kicad_interface.py
  - list_schematic_nets aggregates net names across the top sheet and
    all sub-sheets via the sexp helpers, then resolves connections
    using get_connections_for_net.
  - get_net_connections delegates to get_connections_for_net for
    consistent multi-sheet results.
2026-04-20 15:59:22 -07:00
Noah Piqué
ef42eb60bb fix: correct pin location calculation and symbol reference dedup in kicad-skip
Three bugs fixed in the schematic component and pin locator pipeline:

1. component_schematic: remove redundant symbol.append() after clone()
   kicad-skip's clone() already inserts the raw element into the schematic
   tree. The subsequent NamedCollection.append() detects the reference as
   already registered (from the elementRename triggered by setting
   property.Reference.value) and renames it "R1_" with a trailing
   underscore, causing all subsequent pin lookups to fail.

2. pin_locator: negate lib y coordinate before rotation
   lib_symbols in .kicad_sch use library y-up convention; schematic
   coordinates use y-down. get_pin_location now negates pin_rel_y before
   applying rotation, matching KiCad's own transform order (same approach
   as _transform_local_point in schematic_analysis.py).

3. pin_locator: add .rstrip("_") guard in all symbol reference lookups
   Defensive guard against any residual cases where kicad-skip writes a
   trailing underscore to the Reference property value.

Also fixes the self-test script to use template_with_symbols.kicad_sch
(which contains placed _TEMPLATE_* symbols) rather than the expanded
template (which only contains lib_symbols definitions and has no cloneable
instances).

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-20 13:10:47 +02:00
Noah Piqué
ab2500fb8d fix: correct pin location calculation and symbol reference dedup in kicad-skip
Three bugs fixed in the schematic component and pin locator pipeline:

1. component_schematic: remove redundant symbol.append() after clone()
   kicad-skip's clone() already inserts the raw element into the schematic
   tree. The subsequent NamedCollection.append() detects the reference as
   already registered (from the elementRename triggered by setting
   property.Reference.value) and renames it "R1_" with a trailing
   underscore, causing all subsequent pin lookups to fail.

2. pin_locator: negate lib y coordinate before rotation
   lib_symbols in .kicad_sch use library y-up convention; schematic
   coordinates use y-down. get_pin_location now negates pin_rel_y before
   applying rotation, matching KiCad's own transform order (same approach
   as _transform_local_point in schematic_analysis.py).

3. pin_locator: add .rstrip("_") guard in all symbol reference lookups
   Defensive guard against any residual cases where kicad-skip writes a
   trailing underscore to the Reference property value.

Also fixes the self-test script to use template_with_symbols.kicad_sch
(which contains placed _TEMPLATE_* symbols) rather than the expanded
template (which only contains lib_symbols definitions and has no cloneable
instances).

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-18 23:31:14 +01:00
Eugene Mikhantyev
bfc25639c2 chore: normalize all tracked files to LF line endings
Mechanical application of the `.gitattributes` rules from the prior commit.
All 50 files differ only in line endings — verified by
`git diff --cached --ignore-all-space` being empty.

Before: main had 42 CRLF + 27 LF Python files plus mixed-ending in YAML,
templates, and shell scripts. After: every text file is LF (except the
Windows-native *.ps1, *.bat scripts which remain CRLF per gitattributes).

This eliminates the noisy-diff failure mode seen in PR #102, where a
small logic change produced a 918-line diff due to whole-file CRLF→LF
conversion.
2026-04-18 15:23:00 +01:00
Eugene Mikhantyev
9b1024a8f3 chore: enable strict mypy checks and fix pre-commit mypy hook
Add type annotations to all previously untyped functions and remove 9
suppressed error codes (call-arg, assignment, return-value, operator,
has-type, dict-item, misc, list-item, annotation-unchecked) by fixing
the underlying type issues.

Add [[tool.mypy.overrides]] with ignore_missing_imports for KiCAD-specific
modules (pcbnew, sexpdata, skip, cairosvg, kipy, PIL) so the pre-commit
mypy hook passes in its isolated venv. Add types-requests and pytest to
additional_dependencies in .pre-commit-config.yaml.

Also fixes several real bugs uncovered by stricter checks: incorrect static
calls to instance methods in swig_backend, wrong return type on get_size,
missing value param in BoardAPI.place_component, variable shadowing in
kicad_process.py, unqualified LibraryManager reference in kicad_interface,
and missing top-level Path import.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-05 23:50:54 +01:00
Eugene Mikhantyev
c44bd9205d style: sort Python imports with isort
Add isort configuration (profile=black, line_length=100) to pyproject.toml,
add isort pre-commit hook, and auto-sort imports across all Python source files.

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
2026-03-29 13:02:24 +01:00
Eugene Mikhantyev
75cead0860 style: apply Black formatting to all Python files
Add [tool.black] config to pyproject.toml and Black hook to
.pre-commit-config.yaml (rev 26.3.1), then auto-format all Python
source and test files with line-length=100, target-version=py310.

Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
2026-03-29 13:01:08 +01:00
Eugene Mikhantyev
3e84957698 style: apply Black formatting to pin_locator.py
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-29 12:38:17 +01:00
Eugene Mikhantyev
7d53272cb1 fix: replace hardcoded contributor paths in __main__ blocks
Replace /home/chris/... absolute paths with Path(__file__)-relative
equivalents in wire_manager.py and pin_locator.py so the test
scripts work on any machine.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-29 12:28:27 +01:00
Tom
fec537950f fix: PinLocator resolves pin names (e.g. VCC1, SDA) in addition to pin numbers 2026-03-06 11:38:54 +01:00
Tom
1d390f4fed fix: schematic pin connection reliability
- add_schematic_net_label: warn in description that coords must be exact pin endpoints; recommend connect_to_net instead
- connect_to_net: stub wire direction now follows pin angle (was hardcoded +X)
- pin_locator.py: add get_pin_angle() and _get_lib_id() helpers
- new tool: get_schematic_pin_locations(schematicPath, reference) → returns exact x/y of every pin endpoint, so Claude can place labels correctly
2026-03-06 11:29:52 +01:00
Tom
76503b144c fix: generate_netlist schematic_path, PinLocator cache, server.ts Python detection
- connection_schematic.py: generate_netlist() now accepts schematic_path param,
  threaded through to get_net_connections() so PinLocator is actually invoked
  (previously only 1 connection per component was returned due to fallback break)
- kicad_interface.py: pass schematic_path to generate_netlist()
- pin_locator.py: add _schematic_cache to avoid loading Schematic() once per pin
  (was causing timeout: O(nets x components x pins) Schematic() calls)
- server.ts: remove fragile PYTHONPATH?.includes('KiCad') condition,
  always prefer KiCAD bundled Python on Windows when executable exists
- CHANGELOG.md: document fixes under v2.2.0-alpha
2026-02-28 01:23:36 +01:00
KiCAD MCP Bot
b4d114ac74 fix: Address critical Windows compatibility and JLCPCB issues (#36, #37, #35)
Phase 1 critical fixes addressing three high-priority issues:

Issue #36 - Windows IPC backend crash (os.getuid not available):
- Add platform detection to skip Unix-specific socket paths on Windows
- Use hasattr check before calling os.getuid()
- Windows now uses auto-detect fallback (named pipes)
- Maintains full Unix socket support on Linux/macOS

Issue #37 - Windows schematic file creation broken:
- Generate unique UUIDs instead of invalid all-zeros UUID
- Add explicit UTF-8 encoding for cross-platform compatibility
- Force Unix line endings (LF) to prevent Windows CRLF issues
- Update template file with valid placeholder UUID
- Fix hardcoded /tmp/ paths in wire_manager.py and pin_locator.py

Issue #35 - JLCPCB download limited to 100 parts:
- Change batch_size from 1000 to 100 to match tscircuit API limit
- Remove premature loop termination when batch < batch_size
- Add documentation explaining API limitation
- Expected result: Full ~2.5M part catalog download (40-60 minutes)

All changes maintain backward compatibility and include detailed comments.

Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>
2026-02-26 10:03:20 -05:00
KiCAD MCP Bot
16703e28f9 feat: Integrate WireManager and PinLocator into MCP interface handlers
Updates MCP handlers to use the new wiring infrastructure:

Handler Updates:
- _handle_add_schematic_wire: Uses WireManager.add_wire() with S-expression manipulation
- _handle_add_schematic_connection: Uses ConnectionManager with automatic pin discovery and routing options (direct, orthogonal_h, orthogonal_v)
- _handle_add_schematic_net_label: Uses WireManager.add_label() with support for label types and orientation

Features:
- Automatic pin location discovery with rotation support
- Professional wire routing (direct, orthogonal horizontal-first, orthogonal vertical-first)
- Net label placement with customizable types (label, global_label, hierarchical_label)
- Comprehensive error handling and logging

Testing:
- All MCP handlers tested and verified working
- Integration test: 100% passing (2 wires, 1 label created successfully)
- Verified with kicad-skip that wires and labels are correctly formed

Part of Issue #26 schematic wiring implementation (Phase 1)

Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>
2026-01-10 10:35:16 -05:00