Commit Graph

8 Commits

Author SHA1 Message Date
Eugene Mikhantyev
038beb6d26 refactor: use module-level Symbol constants in delete_wire and delete_label
Replace inline Symbol() allocations with the existing _SYM_WIRE/_SYM_PTS/_SYM_XY
constants and new _SYM_AT/_SYM_LABEL constants for consistency.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-29 12:22:54 +01:00
Eugene Mikhantyev
a11dd5fac9 style: apply Black and Prettier formatting to PR-changed files
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-29 12:22:54 +01:00
Eugene Mikhantyev
3bd3c3a962 feat: add wire/junction tools with pin-snapping and T-junction support
- Rename add_schematic_connection → add_schematic_wire with waypoints[] parameter
- Add snapToPins (default true) to snap wire endpoints to nearest pin
- Expose add_schematic_junction as an MCP tool
- Break existing wires at new wire endpoints for T-junction support
- Remove orphaned add_connection / add_wire / get_pin_location from ConnectionManager
- Update tool registry to reflect renamed schematic tools in TS layer
- Add 76 tests for wire/junction handler dispatch, schema validation, and WireManager corner cases
- Apply Black and Prettier formatting to changed files

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-24 21:46:36 +00:00
Eugene Mikhantyev
f562035f79 test: add schematic tools tests and apply black formatting
- Add python/tests/conftest.py with MagicMock stubs for pcbnew/skip
- Add python/tests/test_schematic_tools.py with 29 tests covering
  WireManager.delete_wire, WireManager.delete_label (unit + integration),
  and parameter validation for all 11 new _handle_* methods
- Apply black formatting to component_schematic.py, wire_manager.py,
  and kicad_interface.py

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-15 22:48:24 +00:00
Eugene Mikhantyev
4dc351660c fix: apply sexpdata round-trip write to delete_schematic_net_label
delete_schematic_net_label was using kicad-skip's write() which silently
discards in-memory _elements mutations. Replaced with WireManager.delete_label()
that uses the same sexpdata round-trip approach already used by delete_schematic_wire.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-13 01:08:49 +00:00
Eugene Mikhantyev
9d9234abd0 fix: replace kicad-skip mutation with sexpdata in delete_schematic_wire
kicad-skip's write() serializes from original parsed data, silently
discarding in-memory _elements mutations. Switch to the same sexpdata
approach used by add_wire: parse, find matching wire, delete the entry,
write back. Also adds WireManager.delete_wire() static method.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-03-13 00:39:23 +00:00
KiCAD MCP Bot
b4d114ac74 fix: Address critical Windows compatibility and JLCPCB issues (#36, #37, #35)
Phase 1 critical fixes addressing three high-priority issues:

Issue #36 - Windows IPC backend crash (os.getuid not available):
- Add platform detection to skip Unix-specific socket paths on Windows
- Use hasattr check before calling os.getuid()
- Windows now uses auto-detect fallback (named pipes)
- Maintains full Unix socket support on Linux/macOS

Issue #37 - Windows schematic file creation broken:
- Generate unique UUIDs instead of invalid all-zeros UUID
- Add explicit UTF-8 encoding for cross-platform compatibility
- Force Unix line endings (LF) to prevent Windows CRLF issues
- Update template file with valid placeholder UUID
- Fix hardcoded /tmp/ paths in wire_manager.py and pin_locator.py

Issue #35 - JLCPCB download limited to 100 parts:
- Change batch_size from 1000 to 100 to match tscircuit API limit
- Remove premature loop termination when batch < batch_size
- Add documentation explaining API limitation
- Expected result: Full ~2.5M part catalog download (40-60 minutes)

All changes maintain backward compatibility and include detailed comments.

Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>
2026-02-26 10:03:20 -05:00
KiCAD MCP Bot
16703e28f9 feat: Integrate WireManager and PinLocator into MCP interface handlers
Updates MCP handlers to use the new wiring infrastructure:

Handler Updates:
- _handle_add_schematic_wire: Uses WireManager.add_wire() with S-expression manipulation
- _handle_add_schematic_connection: Uses ConnectionManager with automatic pin discovery and routing options (direct, orthogonal_h, orthogonal_v)
- _handle_add_schematic_net_label: Uses WireManager.add_label() with support for label types and orientation

Features:
- Automatic pin location discovery with rotation support
- Professional wire routing (direct, orthogonal horizontal-first, orthogonal vertical-first)
- Net label placement with customizable types (label, global_label, hierarchical_label)
- Comprehensive error handling and logging

Testing:
- All MCP handlers tested and verified working
- Integration test: 100% passing (2 wires, 1 label created successfully)
- Verified with kicad-skip that wires and labels are correctly formed

Part of Issue #26 schematic wiring implementation (Phase 1)

Co-Authored-By: Claude Sonnet 4.5 <noreply@anthropic.com>
2026-01-10 10:35:16 -05:00