feat: add export_ipc2581 tool (kicad-cli, with BOM column mapping)
New MCP tool `export_ipc2581` wrapping `kicad-cli pcb export ipc2581`: precision, compression, standard version, units, and the five --bom-col-* field mappings (internal id, mfg P/N, mfg, distributor P/N, distributor) that control the BOM part data embedded in the IPC-2581 file — directly useful for MES/assembly imports that need a real internal P/N rather than the description. Self-contained interface handler reading the saved .kicad_pcb. Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
This commit is contained in:
@@ -449,5 +449,55 @@ export function registerExportTools(server: McpServer, callKicadScript: CommandF
|
||||
},
|
||||
);
|
||||
|
||||
// ------------------------------------------------------
|
||||
// Export IPC-2581 Tool (kicad-cli)
|
||||
// ------------------------------------------------------
|
||||
server.tool(
|
||||
"export_ipc2581",
|
||||
"Export the PCB in IPC-2581 format via kicad-cli. Single-file MES/CAD interchange carrying placement, nets and BOM part data inline. The bomCol* params map schematic fields to the embedded BOM columns (e.g. internal P/N, manufacturer P/N) — useful for assembly/MES imports. Reads the last SAVED state of the .kicad_pcb.",
|
||||
{
|
||||
outputPath: z.string().describe("Output .xml file path"),
|
||||
boardPath: z.string().optional().describe("Path to the .kicad_pcb (default: current board)"),
|
||||
drawingSheet: z.string().optional().describe("Path to a drawing sheet override"),
|
||||
defineVar: z
|
||||
.array(z.string())
|
||||
.optional()
|
||||
.describe("Project variable overrides as 'KEY=VALUE' strings"),
|
||||
precision: z.number().optional().describe("Coordinate precision (default 6)"),
|
||||
compress: z.boolean().optional().describe("Compress the output"),
|
||||
version: z.string().optional().describe("IPC-2581 standard version (default 'C')"),
|
||||
units: z.enum(["mm", "in"]).optional().describe("Units (default mm)"),
|
||||
bomColIntId: z
|
||||
.string()
|
||||
.optional()
|
||||
.describe("Schematic field to use for the BOM Internal Id column"),
|
||||
bomColMfgPn: z
|
||||
.string()
|
||||
.optional()
|
||||
.describe("Schematic field to use for the BOM Manufacturer Part Number column"),
|
||||
bomColMfg: z
|
||||
.string()
|
||||
.optional()
|
||||
.describe("Schematic field to use for the BOM Manufacturer column"),
|
||||
bomColDistPn: z
|
||||
.string()
|
||||
.optional()
|
||||
.describe("Schematic field to use for the BOM Distributor Part Number column"),
|
||||
bomColDist: z.string().optional().describe("Value to insert into the BOM Distributor column"),
|
||||
},
|
||||
async (args) => {
|
||||
logger.debug(`Exporting IPC-2581 to: ${args.outputPath}`);
|
||||
const result = await callKicadScript("export_ipc2581", args);
|
||||
return {
|
||||
content: [
|
||||
{
|
||||
type: "text",
|
||||
text: JSON.stringify(result),
|
||||
},
|
||||
],
|
||||
};
|
||||
},
|
||||
);
|
||||
|
||||
logger.info("Export tools registered");
|
||||
}
|
||||
|
||||