feat: add unit parameter to add_schematic_component for multi-unit symbols
Allows placing a specific unit (A=1, B=2, C=3, …) of a multi-unit KiCad symbol rather than always defaulting to unit 1. Required for quad optocouplers, dual op-amps, and other multi-unit parts where each channel must be placed independently. Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
This commit is contained in:
@@ -402,15 +402,17 @@ class DynamicSymbolLoader:
|
||||
footprint: str = "",
|
||||
x: float = 0,
|
||||
y: float = 0,
|
||||
unit: int = 1,
|
||||
) -> bool:
|
||||
"""
|
||||
Add a component instance to the schematic.
|
||||
This creates the (symbol ...) block with lib_id reference.
|
||||
For multi-unit symbols, set unit to 1–N to place a specific unit.
|
||||
"""
|
||||
full_lib_id = f"{library_name}:{symbol_name}"
|
||||
new_uuid = str(uuid.uuid4())
|
||||
|
||||
instance_block = f""" (symbol (lib_id "{full_lib_id}") (at {x} {y} 0) (unit 1)
|
||||
instance_block = f""" (symbol (lib_id "{full_lib_id}") (at {x} {y} 0) (unit {unit})
|
||||
(in_bom yes) (on_board yes) (dnp no)
|
||||
(uuid "{new_uuid}")
|
||||
(property "Reference" "{reference}" (at {x} {y - 2.54} 0)
|
||||
@@ -429,7 +431,7 @@ class DynamicSymbolLoader:
|
||||
(project "project"
|
||||
(path "/"
|
||||
(reference "{reference}")
|
||||
(unit 1)
|
||||
(unit {unit})
|
||||
)
|
||||
)
|
||||
)
|
||||
@@ -493,6 +495,7 @@ class DynamicSymbolLoader:
|
||||
footprint: str = "",
|
||||
x: float = 0,
|
||||
y: float = 0,
|
||||
unit: int = 1,
|
||||
project_path: Optional[Path] = None,
|
||||
) -> bool:
|
||||
"""
|
||||
@@ -500,6 +503,7 @@ class DynamicSymbolLoader:
|
||||
This is the main entry point for adding components.
|
||||
|
||||
Args:
|
||||
unit: For multi-unit symbols, which unit to place (1=A, 2=B, …). Default 1.
|
||||
project_path: Optional project directory. When set, project-specific
|
||||
sym-lib-table is also searched for the library file.
|
||||
"""
|
||||
@@ -518,6 +522,7 @@ class DynamicSymbolLoader:
|
||||
footprint=footprint,
|
||||
x=x,
|
||||
y=y,
|
||||
unit=unit,
|
||||
)
|
||||
|
||||
|
||||
|
||||
@@ -717,6 +717,7 @@ class KiCADInterface:
|
||||
footprint = component.get("footprint", "")
|
||||
x = component.get("x", 0)
|
||||
y = component.get("y", 0)
|
||||
unit = component.get("unit", 1)
|
||||
|
||||
# Derive project path from schematic path for project-local library resolution
|
||||
schematic_file = Path(schematic_path)
|
||||
@@ -732,6 +733,7 @@ class KiCADInterface:
|
||||
footprint=footprint,
|
||||
x=x,
|
||||
y=y,
|
||||
unit=unit,
|
||||
project_path=derived_project_path,
|
||||
)
|
||||
|
||||
|
||||
@@ -49,6 +49,12 @@ export function registerSchematicTools(server: McpServer, callKicadScript: Funct
|
||||
})
|
||||
.optional()
|
||||
.describe("Position on schematic"),
|
||||
unit: z
|
||||
.number()
|
||||
.int()
|
||||
.min(1)
|
||||
.optional()
|
||||
.describe("Unit number for multi-unit symbols (1=A, 2=B, 3=C, …). Defaults to 1."),
|
||||
},
|
||||
async (args: {
|
||||
schematicPath: string;
|
||||
@@ -57,6 +63,7 @@ export function registerSchematicTools(server: McpServer, callKicadScript: Funct
|
||||
value?: string;
|
||||
footprint?: string;
|
||||
position?: { x: number; y: number };
|
||||
unit?: number;
|
||||
}) => {
|
||||
// Transform to what Python backend expects
|
||||
const [library, symbolName] = args.symbol.includes(":")
|
||||
@@ -74,6 +81,7 @@ export function registerSchematicTools(server: McpServer, callKicadScript: Funct
|
||||
// Python expects flat x, y not nested position
|
||||
x: args.position?.x ?? 0,
|
||||
y: args.position?.y ?? 0,
|
||||
unit: args.unit ?? 1,
|
||||
},
|
||||
};
|
||||
|
||||
|
||||
Reference in New Issue