feat: add get_schematic_view tool for rasterized schematic images
Exports schematic to SVG via kicad-cli, then converts to PNG using cairosvg (same approach as get_board_2d_view). Falls back gracefully to SVG if cairosvg is not installed. Supports configurable output size and format (png/svg). Co-Authored-By: Claude Opus 4.6 <noreply@anthropic.com>
This commit is contained in:
@@ -103,6 +103,7 @@ export const toolCategories: ToolCategory[] = [
|
||||
"list_schematic_labels",
|
||||
"generate_netlist",
|
||||
"sync_schematic_to_board",
|
||||
"get_schematic_view",
|
||||
"export_schematic_svg",
|
||||
"export_schematic_pdf"
|
||||
]
|
||||
|
||||
@@ -888,6 +888,61 @@ Note: operates on .kicad_sch files only. To modify a PCB footprint use edit_comp
|
||||
},
|
||||
);
|
||||
|
||||
// Get schematic view (rasterized image)
|
||||
server.tool(
|
||||
"get_schematic_view",
|
||||
"Return a rasterized image of the schematic (PNG by default, or SVG). Uses kicad-cli to export SVG, then converts to PNG via cairosvg. Use this for visual feedback after placing or wiring components.",
|
||||
{
|
||||
schematicPath: z.string().describe("Path to the .kicad_sch file"),
|
||||
format: z
|
||||
.enum(["png", "svg"])
|
||||
.optional()
|
||||
.describe("Output format (default: png)"),
|
||||
width: z.number().optional().describe("Image width in pixels (default: 1200)"),
|
||||
height: z.number().optional().describe("Image height in pixels (default: 900)"),
|
||||
},
|
||||
async (args: {
|
||||
schematicPath: string;
|
||||
format?: "png" | "svg";
|
||||
width?: number;
|
||||
height?: number;
|
||||
}) => {
|
||||
const result = await callKicadScript("get_schematic_view", args);
|
||||
if (result.success) {
|
||||
if (result.format === "svg") {
|
||||
return {
|
||||
content: [
|
||||
{
|
||||
type: "text",
|
||||
text: result.message
|
||||
? `SVG data returned (${result.message})`
|
||||
: `SVG schematic view (${result.imageData?.length || 0} chars)`,
|
||||
},
|
||||
],
|
||||
};
|
||||
}
|
||||
// PNG — return as base64 image
|
||||
return {
|
||||
content: [
|
||||
{
|
||||
type: "image" as const,
|
||||
data: result.imageData,
|
||||
mimeType: "image/png",
|
||||
},
|
||||
],
|
||||
};
|
||||
}
|
||||
return {
|
||||
content: [
|
||||
{
|
||||
type: "text",
|
||||
text: `Failed to get schematic view: ${result.message || "Unknown error"}`,
|
||||
},
|
||||
],
|
||||
};
|
||||
},
|
||||
);
|
||||
|
||||
// Run Electrical Rules Check (ERC)
|
||||
server.tool(
|
||||
"run_erc",
|
||||
|
||||
Reference in New Issue