fix: reconnect IPC backend after KiCad starts (#140)
Co-authored-by: Copilot <223556219+Copilot@users.noreply.github.com>
This commit is contained in:
23
CHANGELOG.md
23
CHANGELOG.md
@@ -28,6 +28,22 @@ All notable changes to the KiCAD MCP Server project are documented here.
|
||||
`.kicad_sch` path) for stateless callers, so project libraries can be
|
||||
resolved without first calling `open_project`.
|
||||
|
||||
- **IPC backend runtime reconnect**: MCP no longer stays on SWIG for the
|
||||
entire process when it starts before KiCAD. IPC-capable board tools now retry
|
||||
the IPC connection when KiCAD is running, refresh the live board API when a
|
||||
board becomes available, and report `_backend: "ipc"` when they actually use
|
||||
the IPC path. `check_kicad_ui`, `launch_kicad_ui`, and `get_backend_info`
|
||||
now include live backend status instead of only reflecting startup state.
|
||||
|
||||
- **Windows KiCAD Python discovery**: Windows startup now scans per-user KiCAD
|
||||
installs under `%LOCALAPPDATA%\Programs\KiCad` in addition to machine-wide
|
||||
installs under `C:\Program Files\KiCad` and `C:\Program Files (x86)\KiCad`,
|
||||
so user-scope installs no longer require a manual `KICAD_PYTHON` override.
|
||||
|
||||
- **IPC board size on KiCAD 10**: `get_board_info` now handles KiCAD 10 IPC
|
||||
`Box2` objects that expose `pos` / `size` instead of `min` / `max`, avoiding
|
||||
a zero-size board result with an attribute error.
|
||||
|
||||
- **Schematic symbol lookup**: `get_schematic_component`,
|
||||
`edit_schematic_component`, `set_schematic_component_property`,
|
||||
`remove_schematic_component_property`, and `delete_schematic_component`
|
||||
@@ -157,6 +173,9 @@ All notable changes to the KiCAD MCP Server project are documented here.
|
||||
this out explicitly so agents know they can use it to inspect MPN,
|
||||
Manufacturer, Distributor PN and other BOM fields without a separate call.
|
||||
|
||||
- `query_traces`: added to the IPC-capable board command path so trace reads
|
||||
can use live KiCAD board data when IPC is connected.
|
||||
|
||||
### New MCP Prompt
|
||||
|
||||
- `component_sourcing_properties` — Guides the LLM through attaching BOM and
|
||||
@@ -175,6 +194,10 @@ All notable changes to the KiCAD MCP Server project are documented here.
|
||||
no-op removal, special-character escaping, UUID preservation, and the two
|
||||
new convenience tools.
|
||||
|
||||
- `tests/test_backend_metadata.py`: regression coverage for backend metadata,
|
||||
runtime IPC reconnect after KiCAD starts, IPC-backed `query_traces`, and
|
||||
KiCAD 10 IPC `Box2` board-size compatibility.
|
||||
|
||||
### Removed
|
||||
|
||||
- `add_schematic_junction` MCP tool has been removed. Junctions are now
|
||||
|
||||
Reference in New Issue